VOT-320

Configuration using a Web browser en 67

 

 

Idle state

Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is to operate as an NC contact.

Operating mode

Select an operating mode for the relay.

For example, if you want an alarm-activated lamp to stay on after the alarm ends, select Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select

10 s.

Relay follows

If required, select a specific event that will trigger the relay. The following events are possible triggers:

Off

Relay is not triggered by events

Connection

Triggering when connection established

Video alarm

Triggering by interruption of the video signal

Motion alarm

Triggering by motion alarm, as configured on the VCA page (see Section 5.28 Advanced Mode: VCA Event triggered, page 62)

Local input

Triggering by corresponding external alarm input

Remote input

Triggering by remote station's corresponding switching contact (only if a connection exists)

NOTICE!

The numbers in the lists of selectable events relate to the corresponding connections on the camera, Local input 1, for example to the IN1 connection.

Relay name

You can assign a name for the relay here. The name is shown on the button next to Trigger relay. The Livepage can also be configured to display the name under the relay icon. You can also use the name in the Forensic Search program function as a filter option for quick search in recordings.

CAUTION!

Do not use any special characters, for example &, in the name.

Special characters are not supported by the system's internal management.

Trigger relay

Click the button to trigger the relay manually (for testing or to operate a door opener, for example).

Bosch Sicherheitssysteme GmbH

Installation and Operating Manual

DOC V4.5 2010.09

Page 67
Image 67