Configuration using a Web browser en 67 | |
|
|
Idle state
Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is to operate as an NC contact.
Operating mode
Select an operating mode for the relay.
For example, if you want an
10 s.
Relay follows
If required, select a specific event that will trigger the relay. The following events are possible triggers:
–Off
Relay is not triggered by events
–Connection
Triggering when connection established
–Video alarm
Triggering by interruption of the video signal
–Motion alarm
Triggering by motion alarm, as configured on the VCA page (see Section 5.28 Advanced Mode: VCA Event triggered, page 62)
–Local input
Triggering by corresponding external alarm input
–Remote input
Triggering by remote station's corresponding switching contact (only if a connection exists)
NOTICE!
The numbers in the lists of selectable events relate to the corresponding connections on the camera, Local input 1, for example to the IN1 connection.
Relay name
You can assign a name for the relay here. The name is shown on the button next to Trigger relay. The Livepage can also be configured to display the name under the relay icon. You can also use the name in the Forensic Search program function as a filter option for quick search in recordings.
CAUTION!
Do not use any special characters, for example &, in the name.
Special characters are not supported by the system's internal management.
Trigger relay
Click the button to trigger the relay manually (for testing or to operate a door opener, for example).