Bosch Appliances VOT-320 Maintenance and upgrades, Testing the network connection, Camera reset

Models: VOT-320

1 116
Download 116 pages 59.11 Kb
Page 93
Image 93

VOT-320Maintenance and upgrades en 93

7

Maintenance and upgrades

7.1

Testing the network connection

You can use the ping command to check the connection between two IP addresses. This allows you to test whether a unit in the network is active.

1.Open the DOS command prompt.

2.Type ping followed by the IP address of the camera.

If the camera is found, the response appears as Reply from ... followed by the number of bytes sent and the transmission time in milliseconds. If not, the camera cannot be accessed over the network. This might be because:

The camera is not correctly connected to the network. Check the cable connections in this case.

The camera is not correctly integrated into the network. Check the IP address, subnet mask and gateway address.

7.2

Camera reset

 

You can use the Factory Reset button to restore the camera to its original settings. Any

 

changes to the settings are overwritten by the factory defaults. A reset may be necessary, for

 

example, if the camera has invalid settings that prevent it from functioning as desired.

 

 

 

CAUTION!

 

Disconnect the power supply from the mains before opening the housing of the camera.

 

All configured settings will be discarded during a reset.

 

If necessary, back up the current configuration using the Download button on the

 

Maintenance configuration page (see Section 5.39 Advanced Mode: Maintenance, page 77).

 

 

 

 

 

NOTICE!

 

After a reset, the camera can only be addressed via the factory default IP address. The IP

 

address can be changed as described in the Installation chapter (see Section 4.7 Setup using

 

Bosch Video Client, page 22).

 

 

 

 

1.

If necessary, back up the current configuration using the Download button on the

 

 

Maintenance configuration page (see Section 5.39 Advanced Mode: Maintenance,

 

 

page 77).

 

2.

Open the cover of the housing, press the Factory Reset button located on the camera

 

 

module beside the SD slot until the CONNECT LED flashes red (see Section 3.4 Controls

 

 

and displays on the camera module, page 15). All settings will revert to their defaults.

 

3.

Change the IP address of the VOT-320 if necessary.

 

4.

Configure the camera to meet your requirements.

Bosch Sicherheitssysteme GmbH

Installation and Operating Manual

DOC V4.5 2010.09

Page 93
Image 93