54 en Configuration using a Web browser | |
|
|
Connect on alarm
Select On so that the
By setting Follows input 1 the camera maintains the connection that has been automatically established for as long as an alarm exists on alarm input 1.
NOTICE!
In the default setting, Stream 1 is transmitted for alarm connections. Bear this fact in mind when assigning the profile (see Section 5.17 Advanced Mode: Encoder Profile, page 40).
Number of destination IP address
Specify the numbers of the IP addresses to be contacted in the event of an alarm. The camera contacts the remote stations one after the other in the numbered sequence until a connection is made.
Destination IP address
For each number, enter the corresponding IP address for the desired remote station.
Destination password
If the remote station is password protected, enter the password here.
In this page, you can save a maximum of ten destination IP addresses and hence up to ten passwords for connecting to remote stations. If connections to more than ten remote stations are to be possible, for example when initiating connections via
1.In the Number of destination IP address list field, select 10.
2.Enter the address 0.0.0.0 in the Destination IP address field.
3.Enter your chosen password in the Destination password field.
4.Define this password as the user password for all remote stations to which a connection is to be possible.
NOTICE!
If you enter the destination IP address 0.0.0.0 for destination 10, the
Video transmission
If the camera is operated behind a firewall, TCP (HTTP port) should be selected as the transfer protocol. For use in a local network, select UDP.
CAUTION!
Please note that in some circumstances, a larger bandwidth must be available on the network for additional video images in the event of an alarm, in case multicast operation is not possible. To enable multicast operation, select the UDP option for the Video transmission parameter here and on the Network page (see Section Video transmission, page 70).
Stream
Select the stream for transmission in case of an alarm.
DOC V4.5 2010.09 | Installation and Operating Manual | Bosch Sicherheitssysteme GmbH |