Bosch Appliances VOT-320 Snmp host address / 2. Snmp host address, Snmp traps, Authentication

Models: VOT-320

1 116
Download 116 pages 59.11 Kb
Page 74
Image 74

74 en Configuration using a Web browser

VOT-320

 

 

1. SNMP host address / 2. SNMP host address

If you wish to send SNMP traps automatically, enter the IP addresses of one or two required target units here.

SNMP traps

You can select which traps are to be sent.

1.Click Select. A list is opened.

2.Click the checkboxes to select the required traps. All the checked traps will be sent.

3.Click Set to accept the selection.

Authentication

If a RADIUS server is employed in the network for managing access rights, authentication must be activated here to allow communication with the camera. The RADIUS server must also contain the corresponding data.

To configure the camera, you must connect the VOT-320 directly to a computer. This is because communication via the network is not enabled until the Identity and Password parameters have been set and successfully authenticated.

Identity

Enter the name that the RADIUS server is to use for identifying the VOT-320.

Password

Enter the password that is stored in the RADIUS server.

RTSP port

If necessary, select a different port for the exchange of the RTSP data from the list. The standard RTSP port is 554. Select Off to deactivate the RTSP function.

UPnP

You can activate the Universal Plug and Play (UPnP) function. If the function is turned on, the camera responds to requests from the network and is automatically registered on the requesting computers as a new network device. For example, access to the camera can then be made using Windows Explorer without knowledge of the IP address of the camera.

NOTICE!

To use the UPnP function on a computer, both the Universal Plug and Play Device Host and SSDP Discovery Service must be active in Windows XP and Windows Vista.

This function should not be used in large installations because of the variety of potential registration notifications.

TCP port

The device can receive data from an external TCP sender, for example an ATM or POS device, and store it as metadata. Select the port for TCP communication. Select Off to deactivate the TCP metadata function.

Sender IP address

Enter the IP address of the TCP metadata sender here.

DOC V4.5 2010.09

Installation and Operating Manual

Bosch Sicherheitssysteme GmbH

Page 74
Image 74