Chapter 4 Connecting the Cisco uBR7225VXR Router to the Cable Headend

Connecting and Configuring the Upstream

Figure 4-22 Connecting and Configuring the Upstream

Cisco

uBR7225VXR

Upstream

2-way splitter (combiner)

40 dB

attenuator

X-level test point signal level

must be the same for all

optical receivers (+/- 0.5 dB), See Fig. 4-36 and Fig 4-37

10 dB

 

 

 

Optional attenuator

 

X

 

to adjust X-level point

attenuator

 

 

 

 

 

measurement

 

 

 

 

 

 

 

 

Diplex filter

LH To downstream forward

test point on laser transmitter

C

Cable modem

Optical

receiver

271676

Testing the Upstream Configuration

To test the upstream configuration, insert a test signal of known amplitude (+17 dBmV is shown in this example) into the fiber node and measure the amplitude output level at the output of the headend’s optical receiver. This measurement depends on return laser performance and optical distance. This procedure is known as establishing the “X-level” test point. (See Figure 4-23.)

Figure 4-23 The “X-level” Test Point

Spectrum analyzer

Optical

receiver

+17 dBmV

10 km

Fiber node 0.5 milliwatt

Insert +17 dBmV signal

Spectrum analyzer

+11 dBmV

1dB attenuator

 

Optical

 

 

 

receiver

 

Insert +17 dBmV signal

 

 

30 km

Fiber node

 

 

 

 

 

 

 

1.0 milliwatt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure +10 dBmV at this point

 

 

 

 

 

X

 

 

 

 

 

 

14045

 

 

(in this example)

 

X-level test point = +10 dBmV

 

 

 

 

Cisco uBR7225VXR Universal Broadband Router Hardware Installation Guide

 

 

 

 

 

 

OL-17309-02

 

 

4-19

 

 

 

 

 

Page 89
Image 89
Cisco Systems UBR7225VXR Testing the Upstream Configuration, km Fiber node Milliwatt Measure +10 dBmV at this point