4-16
Cisco uBR7225VXR Universal Broadband Router Hardware Installation Guide
OL-17309-02
Chapter4 Connecting the Cisco uBR7225VXR Router to the Cable Headend
Measuring the Downstream RF Signal
Figure4-19 Measuring the RF Signal at the Upconverter Output in CATV Mode—DigitalChannel
Power Screen
Step9 Using the spectrum analyzer’s reference level control, adjust the amplitude of the displayed signal until
the signal peak is within the top graticule of the analyzer’s display grid, as shown in Figure4-20.
Figure4-20 Measuring the RF Signal at the Upconverter Output in CATV Mode—AdjustedDigital
Channel Power Screen
Step10 Select the video averaging feature. Your spectrum analyzer should display a signal similar to the one
shown in Figure4-21.