Communications (continued)

HEAT COMMAND

Allows the user to disable the DPL Heat

 

 

Command, providing compatibility with

 

 

other DATAMAX printers.

 

—ENABLED

Normal printer operating mode.

 

 

 

 

DISABLED

DPL Heat Commands are ignored. The

 

 

heat value is controlled via the menu

 

 

setting; see Print Control, Section 4.1.3.

 

 

SPEED COMMANDS

Allows the user to disable the DPL speed

 

 

commands (Print, Feed, and Reverse).

 

—ENABLED

Normal printer operating mode.

 

 

 

 

DISABLED

DPL speed commands are ignored. The

 

 

print, feed and reverse speeds are

 

 

controlled via the menu setting; see Print

 

 

Control, Section 4.1.3.

I-Class

57

Page 67
Image 67
Datamax 4604, 4212, 4406, 4308, 4208 manual Allows the user to disable the DPL Heat