Advanced Entry Calibration (continued)

Step

Operator Action

 

 

 

 

 

 

Displayed Message

Comment

12

From the data collected in

 

 

 

 

 

 

 

Both sensor

 

 

 

HBJO!USBO!!!!!!=zzz?

 

 

Steps 10 and 11, where

 

 

 

 

 

+11!!!!!!!!!)1!.!42*

 

readings must

 

both the sensor readings are

 

 

Or, for reflective media:

be above 20.

 

above 20, subtract each

 

 

 

 

 

 

 

Label Value from the

 

 

 

 

 

 

 

 

 

 

 

 

corresponding TOF Value.

 

 

HBJO!SFGM!!!!!!=zzz?

 

 

 

 

 

 

+11!!!!!!!!!)1!.!42*

 

 

 

 

These are the Difference

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Values.

 

 

 

 

 

 

 

 

 

 

 

 

From the resulting list, find

 

 

 

 

 

 

 

 

the largest Difference

 

 

 

 

 

 

 

 

 

 

 

 

Value (see example below).

 

 

 

 

 

 

 

 

Its associated Gain Number

 

 

 

 

 

 

 

 

will provide the best

 

 

 

 

 

 

 

 

 

 

 

 

algorithm for your media.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For example, if your

 

 

Gain

 

Label

TOF

Difference

 

 

Number

Value

Value

Value

 

compiled data had the

 

 

 

 

 

00

 

 

 

255

254

 

1

 

values shown in this

 

 

 

 

 

 

 

 

 

 

 

01

 

 

 

251

240

 

11

 

table, Gain Number 8

 

 

 

 

 

 

 

 

 

 

 

02

 

 

 

241

213

 

28

 

would be chosen

 

 

 

 

 

 

 

 

 

 

 

03

 

 

 

231

182

 

49

 

because it has the

 

 

 

 

 

 

 

 

 

 

 

04

 

 

 

219

150

 

69

 

highest Difference

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

05

 

 

 

212

119

 

93

 

Value (146) where

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06

 

 

 

200

88

 

112

 

both the Label Value

 

 

 

07

 

 

 

189

58

 

131

 

and the TOF Value

 

 

 

08

 

 

 

178

32

 

146

 

are above 20.

 

 

 

09

 

 

 

167

19

 

N/A

 

 

 

 

 

 

10

 

 

 

156

17

 

N/A

 

 

 

 

 

 

11

 

 

 

146

16

 

N/A

 

 

 

 

 

 

12

 

 

 

136

15

 

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

31

 

 

 

116

14

 

N/A

 

 

 

 

 

 

32

 

 

 

112

14

 

N/A

 

74

I-Class

Page 84
Image 84
Datamax 4208, 4212, 4406, 4604, 4308 manual Both sensor, Readings must, Be above, Values