Table
Code | Text | Causes | Corrective Actions |
|
|
|
|
E2112 | Mem Spare DIMM | The system BIOS has spared the | See "Troubleshooting System |
| ## | memory because it has | Memory" on page 124. |
|
| determined that the memory had |
|
|
| too many errors. "## & ##" |
|
|
| represents the DIMM pair |
|
|
| implicated by the BIOS. |
|
|
|
|
|
E2113 | Mem Mirror DIMM | They system BIOS has disabled | See "Troubleshooting System |
| ## & ## | memory mirroring because it has | Memory" on page 124. |
|
| determined that one half of the |
|
|
| mirror has had too many errors. |
|
|
| "## & ##" represents the |
|
|
| DIMM pair implicated by the |
|
|
| BIOS. |
|
|
|
|
|
E2118 | Fatal NB Mem CRC | One of the connections in the | See "Troubleshooting System |
|
| Fully Buffered DIMM (FBD) | Memory" on page 124. |
|
| memory subsystem link on the |
|
|
| Northbound side has failed. |
|
|
|
|
|
E2119 | Fatal SB Mem CRC | One of the connections in the | See "Troubleshooting System |
|
| FBD memory subsystem link on | Memory" on page 124. |
|
| the Southbound side has failed. |
|
|
|
|
|
I1910 | Intrusion | System cover has been removed. | Information only. |
|
|
|
|
I1911 | >3 ERRs Chk Log | LCD overflow message. | Check the SEL for details on the |
|
| A maximum of three error | events. |
|
|
|
messages can display sequentially on the LCD. The fourth message displays as the standard overflow message.
I1912 | SEL Full | System Event Log is full of |
|
| events, and is unable to log any |
|
| more events. |
Clear the log by deleting event entries.
W1228 ROMB Batt < 24hr Warns predictively that the RAID battery has less than 24 hours of charge left.
Replace RAID battery. See "Replacing the SAS RAID Controller Daughter Card Battery" on page 96.
NOTE: For the full name of an abbreviation or acronym used in this table, see the "Glossary" on page 169.
About Your System