Table
Message | Causes | Corrective Actions |
|
|
|
PCI BIOS failed to install | PCI device BIOS (Option ROM) | Reseat the expansion cards. Ensure that |
| checksum failure is detected during | all appropriate cables are securely |
| shadowing. Loose cables to expansion | connected to the expansion cards. If the |
| card(s); faulty or improperly installed | problem persists, see "Troubleshooting |
| expansion card. | Expansion Cards" on page 131. |
|
|
|
Plug & Play Configuration | Error encountered in initializing PCI | Install the NVRAM_CLR jumper and |
Error | device; faulty system board. | reboot the system. See Figure |
|
| jumper location. If the problem persists, |
|
| see "Troubleshooting Expansion Cards" |
|
| on page 131. |
Read fault
Requested sector not found
The operating system cannot read from the diskette or hard drive, the system could not find a particular sector on the disk, or the requested sector is defective.
Replace the diskette. Ensure that the diskette and hard drive cables are properly connected. See "Troubleshooting a USB Device" on page 119, "Troubleshooting a Diskette Drive" on page 126, or "Troubleshooting a Hard Drive" on page 129 for the appropriate drive(s) installed in your system.
Remote configuration | System unable to process Remote | Retry Remote Configuration. |
update attempt failed | Configuration request. |
|
|
|
|
ROM bad checksum = address | Expansion card improperly installed or | Reseat the expansion cards. Ensure that |
| faulty. | all appropriate cables are securely |
|
| connected to the expansion cards. If the |
|
| problem persists, see "Troubleshooting |
|
| Expansion Cards" on page 131. |
|
|
|
Sector not found | Faulty diskette or hard drive. | See "Troubleshooting a Diskette Drive" |
Seek error |
| on page 126 or "Troubleshooting a Hard |
| Drive" on page 129 for the appropriate | |
Seek operation failed |
| |
| drive(s) installed in your system. | |
|
| |
|
|
|
Shutdown failure | Shutdown test failure. | See "Troubleshooting System Memory" |
|
| on page 124. |
The amount | of system | Memory has been added or removed |
memory has | changed | or a memory module may be faulty. |
If memory has been added or removed, this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if