Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.
Temperature
Maximum temperature gradient (operating and storage)
Storage temperature limits
Relative humidity
Storage
Temperature (continuous operation)
Temperature ranges (for altitude less than 950 m or 3117 ft)
20°C/h (36°F/h)
5% to 95% RH with 33°C (91 °F) maximum dew point. Atmosphere must be
10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
NOTE: For information on restrictions, see Standard Operating Temperature.
Fresh air | For information on fresh air, see Expanded |
| Operating Temperature. |
Humidity percentage range | 10% to 80% Relative Humidity with 26°C |
| (78.8°F) maximum dew point. |
Maximum vibration |
|
Operating | 0.26 Grms at 5 Hz to 350 Hz (all operation |
| orientations). |
Storage | 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six |
| sides tested). |
Maximum shock |
|
Operating | One shock pulse in the positive z axis of 31 G |
| for 2.6 ms in all operational orientations. |
Storage | Six consecutively executed shock pulses in the |
| positive and negative x, y, and z axes (one pulse |
| on each side of the system) of 71 G for up to 2 |
| ms. |
Maximum altitude |
|
Operating | 3,048 m (10,000 ft) |
Storage | 12,000 m (39,370 ft). |
Operating altitude |
|
Up to 35°C (95°F) | Maximum temperature is reduced by 1°C/300 |
| m (1°F/547 ft) above 950 m (3,117 ft). |
158