Symptom

Cause/Solution

Page

Cannot login to

 

• Login information is incorrect. Check if the Username for Napster

42, 103

Napster. (“Incorrect

 

has been properly entered. Re-enter the Password. (Password is

 

Username or

 

not displayed.)

 

Password” is

 

http://www.napster.com/choose/index_default.html

 

displayed.)

 

 

 

Cannot login to

 

• Login information is incorrect. Check if the “Email address” for

44

Pandora. (“Email

 

Pandora has been properly entered. Re-enter the “Password”.

 

address” or

 

(Password is not displayed.)

 

“Password” is

 

http://www.pandora.com/denon

 

displayed.)

 

 

 

GRemote Control UnitH

 

 

Symptom

Cause/Solution

Page

The set cannot be

 

• Batteries are worn out. Replace with new batteries.

124

operated with the

 

• Operate the remote control unit within a distance of about 23 ft /

124

remote control unit.

 

7 m from this unit and at an angle of within 30°.

 

 

 

• Remove any obstacle between this unit and the remote control

124

 

 

unit.

 

 

 

• Insert the batteries in the proper direction, checking the q and

124

 

 

w marks.

 

 

 

• The set’s remote control sensor is exposed to strong light (direct

124

 

 

sunlight, inverter type fluorescent bulb light, etc.). Move the set

 

 

 

to a place in which the remote control sensor will not be exposed

 

 

 

to strong light.

 

 

 

• Make sure the remote control IDs of the main unit and remote

105, 114,

 

 

control unit match. If the IDs do not match, “AVAMPz” (z is the

118

 

 

main unit’s remote control ID) appears on the display of this unit

 

 

 

when the remote control unit is operated.

 

 

 

• The ZONE SELECT setting is not correct. Press ZONE SELECT to

108

 

 

select the zone to operate.

 

 

 

• The operation mode does not match the settings of the device to

108

 

 

operate. Check the operation mode.

 

Resetting the microprocessor

Perform this procedure if the display is abnormal or if operations cannot be performed. When the microprocessor is reset, all the settings are reset to their default values.

ON/STANDBY STANDARDDSP SIMULATION

1 Turn off the power using ON/STANDBY.

2 Press ON/STANDBY while simultaneously pressing STANDARD and DSP SIMULATION.

3 Once the display starts flashing at intervals of about 1 second, release the two buttons.

If in step 3 the display does not flash at intervals of about 1 second, start over from step 1.

138