Table A-7. 2051T In-Line Pressure Transmitter Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model Transm itt er Typ e
2051T In-Line Pressure Transmitter
Pressure Type
Standard Standard
GGage
A(1) Absolute
Pressure Range
2051TG(2) 2051TA
Standard Standard
1-14.7 to 30 psi (-1.0 to 2.1 bar) 0 to 30 psia (0 to 2.1 bar)
2-14.7 to 150 psi (-1.0 to 10.3 bar) 0 to 150 psia (0 to 10.3 bar)
3-14.7 to 800 psi (-1.0 to 55 bar) 0 to 800 psia (0 to 55 bar)
4-14.7 to 4000 psi (-1.0 to 276 bar) 0 to4000 psia (0 to 276 bar)
5-14.7 to 10000 psi (-1.0 to 689 bar) 0 to10000 psia (0 to 689 bar)
Transm itt er O utpu t
Standard Standard
XWireless
Process Connection Style
Standard Standard
2B 1/2–14 NPT Female
2C(3) G½ A DIN 16288 Male (Available in SST for Range 1–4 only)
Isolating Diaphragm Process Connection Wetted Parts Material
Standard Standard
2(4) 316L SST 316L SST
3(4) Alloy C-276 Alloy C-276
Sensor Fill Fluid
Standard Standard
1Silicone
Housing Material Conduit Entry Size
Standard Standard
PEngineered Polymer with Aluminum Module Material N/A
Wireless Options (Requires Wireless output code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard Standard
WA3 User Configurable Transmit Rate, 2.4 GHz WirelessHART
Antenna and SmartPower
Standard Standard
WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
Options (Include with selected model number)
Manifold Assemblies
Standard Standard
S5(5) Assemble to Rosemount 306 Integral Manifold
Seal Assemblies
Standard Standard
S1(5) Assemble to one Rosemount 1199 seal