Table A-9. Rosemount 2051CFA Annubar Flowmeter Ordering Information

The Standard offering represents the most common options. The starred options () should be selected for best delivery.

The Expanded offering is subject to additional delivery lead time.

Expanded

 

 

 

G1

Needle Valves, Carbon Steel

 

 

G3

Needle Valves, Alloy C-276

 

 

G5

OS&Y Gate Valve, Carbon Steel

 

 

G7

OS&Y Gate Valve, Alloy C-276

 

 

Special Shipment

 

 

Standard

 

 

Standard

Y1

Mounting Hardware Shipped Separately

 

Special Dimensions

 

 

Expanded

 

 

 

VM

Variable Mounting

 

 

VT

Variable Tip

 

 

VS

Variable length Spool Section

 

 

Product

Certifications

 

 

Standard

 

 

Standard

I1

ATEX Intrinsic Safety

 

I2

INMETRO Intrinsic Safety

 

I3

China Intrinsic Safety

 

I4

TIIS Intrinsic Safety

 

I5

FM Intrinsically Safe, Division 2

 

I6

CSA Intrinsic Safety

 

I7

IECEx Intrinsic Safety

 

Sensor Fill

Fluid and O-ring Options

 

 

Standard

 

 

Standard

L2

Graphite-Filled (PTFE) O-ring

 

Display and

Interface Options

 

 

Standard

 

 

Standard

M5

LCD Display

 

Transmitter

Calibration Certification

 

 

Standard

 

 

Standard

Q4

Calibration Certificate for Transmitter

 

Manifold for

Remote Mount Option

 

 

Standard

 

 

Standard

F2

3-Valve Manifold, Stainless Steel

 

F6

5-Valve Manifold, Stainless Steel

 

Expanded

 

 

 

F1

3-Valve Manifold, Carbon Steel

 

 

F3

3-Valve Manifold, Alloy C-276

 

 

F5

5-Valve Manifold, Carbon Steel

 

 

F7

5-Valve Manifold, Alloy C-276

 

 

Hardware

Adjustments

 

 

Standard

 

 

Standard

DZ

Digital Zero Sensor Trim Configuration Button

 

Typical Model

 

 

Number:

2051CFA D L 060 D C H P S 2 T1 0 0

0 3 2 X P 1 WA3 WP5 M5

 

 

 

 

 

(1)Available in remote mount applications only.

(2)Applies to assembled flowmeter only, mounting not tested.

(3)Instrument Connections for Remote Mount Options and Isolation Valves for Flo-tap Models are not included in the Material Traceability Certification.

(4)Not available with Transmitter Connection Platform 6.

(5)Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

Specifications and Reference Data

119

Page 131