Reference Manual

Appendix A: Reference Data

00809-0100-4102, Rev AA

May 2013

Table A-6. 2051C Coplanar Pressure Transmitters Ordering Information

The Standard offering represents the most common options. The starred options () should be selected for best delivery.

The Expanded offering is subject to additional delivery lead time.

RC1/4 RC1/2 Process Connection

 

Expanded

 

 

D9(14)

RC ¼ Flange with RC ½ Flange Adapter, CS - SST

 

Max Static Line Pressure

 

 

 

 

Standard

 

Standard

P9

4500 psig (310 bar) Static Pressure Limit (2051CD Ranges 2–5 only)

Surface Finish

 

 

 

 

Standard

 

Standard

Q16

Surface finish certification for sanitary remote seals

Toolkit Total System Performance Reports

 

 

 

 

Standard

 

Standard

QZ

Remote Seal System Performance Calculation Report

Typical Model Number: 2051CD 2 X 2 2 A 1 P WA3 WP5 B4 M5

 

 

 

 

(1)Wireless output (code X) available in absolute measurement type (code A) with only range 1-4, 316 SST isolating diaphragm material (code 2), silicone fill fluid (code 1), and housing code (code P).

(2)2051CD0 is available only with Output Code A, Process Flange Code 0 (Alternate Flange H2, H7, HJ, or HK), Isolating Diaphragm Code 2, O-ring Code A, and Bolting Option L4.

(3)Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

(4)Requires 0 code in Materials of Construction for Alternate Process Connection.

(5)Not valid with optional code P9 for 4500 psi Static Pressure.

(6)Process Flange limited to Coplanar (codes 2, 3, 5, 7, 8) or Traditional (H2, H3, H7).

(7)Not valid with optional code D9 for RC1/2 Adaptors.

(8)Not valid for optional codes DF and D9 for Adaptors.

(9)“Assemble-to” items are specified separately and require a completed model number.

(10)Not available with Alloy C-276 isolator (3 code), tantalum isolator (5 code), all cast C-276 flanges, all plated CS flanges, all DIN flanges, all Level flanges, assemble-to manifolds (S5 and S6 codes), assemble-to seals (S1 and S2 codes), assemble-to primary elements (S3 and S4 codes), surface finish certification (Q16 code), and remote seal system report (QZ code).

(11)Not available with Fieldbus (output code F) or Profibus (output code W).

(12)High Performance Option includes 0.04% Reference Accuracy. See Performance Specifications for details.

(13)Not valid with Alternate Process Connection options S3, S4, S5, and S6.

(14)Not available with Alternate Process Connection; DIN Flanges and Level Flanges.

Specifications and Reference Data

107

Page 119
Image 119
Emerson 00809-0100-4102 manual RC1/4 RC1/2 Process Connection, Max Static Line Pressure, Surface Finish