Rosemount 2051 Wireless Pressure Transmitters
Page
Reference Manual
Rosemount 2051 Wireless Pressure, Flow, and Level Solutions
Explosions could result in death or serious injury
Iii
Reference Manual
Contents
Table of Contents Reference Manual
Installation
Operation and maintenance
Troubleshooting
Commissioning
Appendix B Product Certifications
Appendix a Specifications Reference Data
Appendix D Network design best practices
Appendix C Field Communicator Menu Trees and Fast Keys
Table of Contents Reference Manual
Models covered
Using this manual
Rosemount 2051C Coplanar Pressure Transmitter
Rosemount 2051T in-line Pressure Transmitter
Rosemount 2051L Level Transmitter
Rosemount 2051CF Flowmeters
Introduction Reference Manual
WirelessHART installation flowchart
WirelessHART installation flowchart
LCD Display
Transmitter overview
Wireless considerations
Considerations before transmitter installation
Power up sequence
Antenna position
Electrical
Mechanical
Service support
Temperature effects
Environmental
Product Recycling/Disposal
Overview
Safety messages
Required bench top configuration
AMS Wireless Configurator
Configuration Reference Manual
Connection diagrams
Basic setup
Set device tag
Bench hook-up
Select 1 Guided Setup Select 3 Join Device to Network
Configure update rate
Select 1 Guided Setup Select 4 Configure Update Rate
Join device to network
Remove Power Module
Configure for Pressure
Select 2 Manual Setup Select 2 Pressure
Set process variable units
Re-mapping using AMS Device Manager
Re-mapping using a Field Communicator
Set range points
Variable Mapping
Setting transmitter output with a Field Communicator
Setting transmitter output with AMS Device Manager
Set transmitter percent of range transfer function
Configuring scaled variable
Configure for Level and Flow
Configuring Scaled Variable using a Field Communicator
Configuring Scaled Variable using AMS Device Manager
Scaled Variable Configuration for Tank Application
DP Level Example
DP Flow example
Scaled Variable Configuration for Flow Application
Set range points
Select 2 Manual Setup Select 9 Device Information
Review configuration data
Review pressure information
Review device information
Review operating parameters
Review radio information
Select 7 Device Information
Select 2 Variables
Configuring LCD display with a Field Communicator
Configuring the LCD display
Configuring LCD display with AMS Device Manager
Click Manual Setup, select the Display tab
Configure process alerts
Detailed transmitter setup
Select 1 Guided Setup
Damping
Write protect
Diagnostics and service
Join status
Device reset
Number of available neighbors
Saving, Recalling, and Cloning Configuration Data
Advanced Functions for Hart Protocol
Field Communicator
AMS creating a Reusable Copy
AMS Applying a User Configuration
Section Installation
Installation Reference Manual
Installation considerations
Reference Manual Installation
Considerations
Mechanical considerations
Steam service
Environmental considerations
Internal antenna position
Draft range considerations
Installation Flowchart
Reducing process noise
Output damping
Reference side filtering
Consider housing rotation
Installation procedures
Power Module side of electronics housing
Circuit side of electronics housing
Mount the transmitter
Environmental seal for housing
Mounting brackets
Mounting brackets
Mounting bracket option code B4
Flange bolts
Bolt Material Initial Torque Value Final Torque Value
Bolt Installation Torque Values
Description Qty
Size
Panel mounting bracket option codes B2 and B8
Best practices
Impulse piping
Liquid Flow Measurement
Mounting Requirements
Coplanar or traditional process connection
Process connections
Flange adapters
Drain/vent valves
Inline gage transmitter orientation
Inline process connection
13. Power Module
Power Module installation
Installing the LCD display
14. Optional LCD Display
Rosemount 304, 305 and 306 integral manifolds
15. Integral Manifold Designs
Rosemount 305 Integral Manifold installation procedure
16. Bolt tightening pattern
Rosemount 306 Integral Manifold installation procedure
Manifold operation
Rosemount 304 Conventional Manifold installation procedure
Transmitter to service
Configuration for zeroing
To zero the 2051, close Block valve to the low
Pressure downstream side Transmitter first
Test
Transmitter. The manifold is
Open the equalize valve on Low pressure Downstream side
Now in the proper
Close the equalize valve on High pressure upstream Side
Installation
Section
Commissioning Reference Manual
Viewing network status
Verifying operation
Local Display
Function Key Sequence Menu Items
Smart Wireless Gateway
Device Manager
Smart Wireless Gateway Explorer
Smart Wireless Gateway Network Settings
Using the Field Communicator
Rosemount 2051 Wireless Fast Key Sequence
Configuring transmitter security
Hart lock
Reference Manual Commissioning
Configuring Hart Lock using Field Communicator
Configuring Hart Lock using AMS Device Manager
Configuration Button lock
Calibration overview
Operation and maintenance
Determining necessary Sensor Trims
Operation and Maintenance Reference Manual
Recommended Calibration Tasks
Transmitter Bench Calibration Tasks Field Calibration Tasks
Determining calibration frequency
Trimming with configuration buttons
Calculate calibration frequency
Sensor Trim Overview
Trim the pressure signal
Example
HT = URV S/100 x P/1000 x LRV
Sensor Trim example
Sensor Trim
Performing a Sensor Trim with a Field Communicator
Select 5 Maintenance Select 1 Pressure Calibration
Performing a Sensor Trim with AMS Device Manager
Performing a Digital Zero Trim option DZ
Recall Factory Trim-Sensor Trim
Line Pressure Effect Range 2 and Range
Compensating for Line Pressure Range 4 and Range
Zero Effect
LT = 500 + 0.01/10005001200 506 inH2O 1.26 bar
Startup Screen Sequence
LCD Screen Messages
S R
13 0
Diagnostic Button Screen Sequence
T w k K n w n
Network Diagnostic Status Screens
C H N G
Operation and maintenance
I l u r
Device Diagnostic Screens
C d e
D i o I l u r
N f g R n
Troubleshooting
Troubleshooting Reference Manual
Rosemount 2051 Wireless Device Status Information
Device Status Description Recommended Action
Check process for possible saturation condition
Reference Manual Troubleshooting
Check the buttons for obstructions
Rosemount 2051 Wireless Troubleshooting
Symptom Recommended Actions
Wireless Network Troubleshooting
Removing from service
Performance Specifications
Conformance to specification ±3σ Sigma
Digital output
Total Performance
Reference Accuracy1
Appendix a Reference Data Reference Manual
Models Standard
Long Term Stability
Dynamic Performance
Line Pressure Effect per 1000 psi 6,9 MPa1
Ambient Temperature Effect per 50F 28C
Service
Mounting Position Effects
Vibration Effect
Range and Sensor Limits
Wireless Self-Organizing Networks
Overpressure limits
Temperature limits
Static pressure limit
Burst pressure limits
Process Temperature Limits
Volumetric Displacement
Humidity Limits
2051C Coplanar
Physical specifications
Electrical connections
Process-Wetted parts
Non-Wetted Parts
Rosemount 2051L Process Wetted Parts
Sensor Module Fill Fluid
Table A-2. Transmitter weights without options
Shipping Weights for 2051 Wireless Pressure Transmitter
Table A-3 L weights without options
Table A-4. Transmitter option weights
Dimensional Drawings
Pipe Process Lower Housing G Class Size Side F NPT
Table A-5 L Dimensional Specifications
Outside Extension Pipe
Diameter Gasket Class Size
Ordering Information
Wireless Transmit Rate, Operating Frequency and Protocol
Housing Material Conduit Entry Size
Antenna and SmartPower
Manifold Assembly59
All-Welded Seal Assemblies for high vacuum applications9
Seal Assemblies9
Mounting Bracket
Product Certifications
Software Configuration
Hardware Adjustments
Pressure Testing
Cleaning Process Area
Max Static Line Pressure
RC1/4 RC1/2 Process Connection
Surface Finish
Toolkit Total System Performance Reports
Options
Wireless Sensor Module
Zero/Span Adjustment
Calibration Certification
Process Area8
Typical Model Number 2051T G 5 X 2A 2 1 P WA3 WP5 B4 M5
Model
Code Process Connection Size Material Extension Length
Mounting Flange Size, Rating, Material High Side
Low Pressure Side Flange Configuration Adapter
Bolting Material Standard
Calibration Certification Standard
Material Traceability Certification Standard
Software Configuration Standard
Hardware Adjustments Standard
Toolkit Total System Performance Reports Standard
Ring Material Number Size NPT Standard
Model Product Description
Line Size
Pipe I.D. Range
Piping Orientation
Pipe Material / Mounting Assembly Material
Annubar Type
Sensor Material
Transmitter Housing Material Conduit Entry Size
Temperature Measurement
Opposite Side Support or Packing Gland
Isolation Valve for Flo-Tap Models
QC1
Fluid and O-ring Options Standard
Primary Element Technology
Material Type
Primary Element Type
Transmitter Housing Material
ANSI/ASME B31.1 ANSI/ASME B31.3 ANSI/ASME B31.8
Process Connection
Body Material
Orifice Plate Material
Bore Size Option
Differential Pressure Ranges
Options
LCD Display Hardware Adjustments Standard
Options
Output information
Configuration buttons
Display and interface options
Bolts for flanges and adapters
Rosemount 2051C Traditional Flange bracket options
Spare parts
Approved manufacturing locations
Wireless Certifications
European directive information
Telecommunication compliance
North American certifications
Ordinary location certification for FM
CSA Canadian Standards Association
European certifications
注意!
134
Field Communicator menu trees
Appendix C Field Communicator Menu Trees and Fast Keys
Appendix C Field Communicator Menu Trees Reference Manual
Guided Setup
137
138
Effective range
Appendix D Network design best practices
Appendix D Network design best practices
Appendix D Network design best practices Reference Manual
Page
Latin America