Table A-10. Rosemount 2051CFC Compact Flowmeter Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model Product Description
2051CFC Compact Flowmeter
Measurement Type
Standard Standard
DDifferential Pressure
Primary Element Technology
Standard Standard
CConditioning Orifice Plate
POrifice Plate
AAnnubar® Averaging Pitot Tube
Material Type
Standard Standard
S316 SST
Line Size
Standard Standard
005(1) 1/2-in. (15 mm)
010(1) 1-in. (25 mm)
015(1) 11/2-in. (40 mm)
020 2-in. (50 mm)
030 3-in. (80 mm)
040 4-in. (100 mm)
060 6-in. (150 mm)
080 8-in. (200 mm)
100(2) 10-in. (250 mm)
120 12-in. (300 mm)
Primary Element Type
Standard Standard
N000 Annubar Sensor Size 1
N040 0.40 Beta Ratio
N065(3) 0.65 Beta Ratio
Temperature Measurement
Standard Standard
0No Temperature Sensor
Expanded
RRemote Thermowell and RTD
Transmitter Connection Platform
Standard Standard
3Direct Mount
7Remote-mount, NPT Connections
Differential Pressure Range
Standard Standard
10 to 25 in H2O (0 to 62,3 mbar)
20 to 250 in H2O (0 to 623 mbar)
30 to 1000 in H2O (0 to 2,5 bar)
Transm itt er O utpu t
Standard Standard
XWireless