111
Reference Manual
00809-0100-4102, Rev AA
Appendix A: Reference Data
May 2013
Specifications and Reference Data
Table A-8. Rosemount 2051L Liquid Level Transmitter Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model Trans mit ter Type
2051L Liquid Level Transmitter
Pressure Range
Standard Standard
2–250 to 250 inH2O (–0,6 to 0,6 bar)
3–1000 to 1000 inH2O (–2,5 to 2,5 bar)
4–300 to 300 psi (–20,7 to 20,7 bar)
Transm itt er O utpu t
Standard Standard
XWireless
Process Connection Size, Material, Extension length (High Side)
Standard Standard
Code Process Connection Size Material Extension Length
G0(1) 2-in./DN 50 316L SST Flush Mount Only
H0(1) 2-in./DN 50 Alloy C-276 Flush Mount Only
J0 2-in./DN 50 Tanta lum Flush Mount Only
A0(1) 3-in./DN 80 316L SST Flush Mount
A2(1) 3-in./DN 80 316L SST 2-in./50 mm
A4(1) 3-in./DN 80 316L SST 4-in./100 mm
A6(1) 3-in./DN 80 316L SST 6-in./150 mm
B0(1) 4-in./DN 100 316L SST Flush Mount
B2(1) 4-in./DN 100 316L SST 2-in./50 mm
B4(1) 4-in./DN 100 316L SST 4-in./100 mm
B6(1) 4-in./DN 100 316L SST 6-in./150 mm
C0(1) 3-in./DN 80 Alloy C-276 Flush Mount
C2(1) 3-in./DN 80 Alloy C-276 2-in./50 mm
C4(1) 3-in./DN 80 Alloy C-276 4-in./100 mm
C6(1) 3-in./DN 80 Alloy C-276 6-in./150 mm
D0(1) 4-in./DN 100 Alloy C-276 Flush Mount
D2(1) 4-in./DN 100 Alloy C-276 2-in./50 mm
D4(1) 4-in./DN 100 Alloy C-276 4-in./100 mm
D6(1) 4-in./DN 100 Alloy C-276 6-in./150 mm
E0 3-in./DN 80 Tanta lum Flush Mount Only
F0 4-in./DN 100 Tant alum Flush Mount Only
Mounting Flange Size, Rating, Material (High Side)
Size Rating Material
Standard Standard
M2-in. ANSI/ASME B16.5 Class 150 CS
A3-in. ANSI/ASME B16.5 Class 150 CS
B4-in. ANSI/ASME B16.5 Class 150 CS
N2-in. ANSI/ASME B16.5 Class 300 CS
C3-in. ANSI/ASME B16.5 Class 300 CS
D4-in. ANSI/ASME B16.5 Class 300 CS