Appendix B: Product Certifications

Reference Manual

May 2013

00809-0100-4102, Rev AA

B.1.5

Ordinary location certification for FM

 

As standard, the transmitter has been examined and tested to determine that the design meets

 

basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized

 

testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health

 

Administration (OSHA).

B.1.6

North American certifications

 

Factory Mutual (FM) approvals

 

I5

FM Intrinsically Safe

 

 

Certificate No: 3045342

 

 

Applicable Standards: Class 3600:2011, Class 3610:2010, Class 3810:2005

 

 

Markings: Intrinsically Safe for Class 1, Division 1, Groups A, B, C, D

 

 

Zone Marking: Class 1 Zone 0, AEx ia IIC

 

 

T4 (-40 °C to 70 °C)

 

 

Intrinsically Safe when installed according to Rosemount Drawing 03031-1062

 

 

Enclosure Type 4X / IP66/68

 

Specific Conditions for Safe Use:

 

1. The Model 2051 Wireless pressure Transmitter shall only be used with the 701PGNKF

 

 

Rosemount Smartpower Battery Pack.

 

2. The inline pressure sensor may contain more than 10% aluminum and is considered a

 

 

potential risk of ignition by impact or friction. Care must be taken into account during

 

 

installation and use to prevent impact and friction.

 

3. The surface resistivity of the transmitter housing is greater than one gigaohm. To avoid

 

 

electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry

 

 

cloth.

B.1.7

CSA - Canadian Standards Association

 

I6

CSA Intrinsically Safe

 

 

Certificate No: 2526009

 

 

Applicable Standards: CSA 22.2 No. 0-M91, CSA C22.2 No. 159-92

 

 

Markings: Intrinsically Safe For Class 1, Division 1, Groups A, B, C, D

 

 

T4 (-40 °C to 70 °C)

 

 

Intrinsically safe when installed according to Rosemount drawing 03031-1063

 

 

Enclosure Type 4X/IP66/IP68

B.1.8

European certifications

 

I1

ATEX Intrinsic Safety

 

 

Certificate No.: Baseefa12ATEX0228X

Applicable Standards: EN60079-11:2012, EN60079-0:2012

Markings: Ex ia IIC T4 Ga (-40 °C ≤ Ta ≤ 70 °C)

II 1G

IP66/68

1180