Stylus C40UX/C40SX/C20UX/C20SX

Revision A

1.3.6 Envirormental Condition

† Temperature

: 10 to 35 ºC (operating *3 )

 

: -20 to 60 ºC(non-operating, *1)

 

1 month at 40 ºC

 

120 hours at 60 ºC

† Humidity

: 20 to 80% RH (operating, *2,*3)

 

: 5 to 85% RH (non-operating, *1, *2)

† Resistance to shock

: 1 G, within 1 ms (operating)

 

: 2 G, within 2 ms (non-operating, *1)

† Resistance to vibration

: 0.15G (operating)

 

: 0.50G (non-operating, *1)

*1: with shipment container

*2: without condensation

*3: Condition is as following figure.

Figure 1-2. Environmental Condition

1.3.7 Reliability

† Total print volume

: 10,000 pages (A4, Letter) or

 

20,000 pages (A4, Letter)

 

*refer to “EEPROM Address Map” on page -102

† Print Head Life

: 4000 million dots/nozzle

1.3.8 Safety Approvals

†120 V version :

Safety standards : UL1950 with D3

CSA C22.2 No.950 with D3

EMI : FCC part15 subpart B class B

CSA C108.8 class B

†220-240 V version :

Safety standards : EN 60950(VDE)

EMI : EN 55022(CISPR Pub.22) class B

:AS/NZS 3548 class B

1.3.9Acoustic Noise

† Level

: Approx. 45 dB(A) (According to ISO 7779)

1.3.10 CE Marking

†220-240 V version

Low Voltage Directive 73/23/EEC : EN60950

EMC Directive 89/336/EEC : EN55022 Class B

EN61000-3-2

EN61000-3-3

EN50082-1

IEC801-2

IEC801-3

IEC801-4

PRODUCT DESCRIPTION

SECIFICATIONS

12

Page 12
Image 12
Epson C40UX service manual Envirormental Condition, Reliability, Safety Approvals, Acoustic Noise, CE Marking