Stylus C40UX/C40SX/C20UX/C20SX

Revision A

.

Table 3-20. Print quality is not good

Step

Detail phenomenon

Check point

Remedy

No.

 

 

 

 

 

 

 

Table 3-21. Print quality is not good

Step

Detail phenomenon

Check point

Remedy

No.

 

 

 

 

 

 

 

1

Vertical banding is appeared against the CR movement direction. And it looks like uneven printing.

CR movement

direction

1.Check if each segment is printed correctly in the nozzle check pattern.

2.Check if the CR rail on the main frame is not extremely dirty, etc.

3.Check if the surface of the CR sliding portion on the Paper eject frame has enough oil.

G-58 lubrication

4.Check if the surface of the Paper eject frame is flat.

1.Perform the CL and check the nozzle check pattern.

2.Clean the CR rail on the main frame and lubricate G-58.

3.Clean the surface of the CR sliding portion on the Paper eject frame and lubricate specific amount of the G-58.

4.Replace the Paper eject frame with new one.

 

 

 

 

 

 

 

5.

Replace the following

 

 

 

 

 

 

 

 

parts.

1

Ditto

 

CR motor

 

 

 

 

 

 

 

CR timing belt

 

 

 

 

 

 

 

Compression spring 11.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Check if each segment

1.

Perform the CL and

 

 

 

 

 

 

is printed correctly in

 

check the nozzle check

 

 

 

 

 

 

the nozzle check

 

pattern. by using the

 

 

 

 

 

 

pattern.

 

Adjustment program.

 

Micro banding appears

2. Check if the suitable

2.

Use the suitable paper

 

paper is used

 

according to the printer

 

horizontally against the

according to the

 

driver setting.

 

paper feeding direction

printer driver setting.

 

 

 

and it appears with the

3. Check if the Paper

3.

Clean the surface of the

 

same width.

 

feed roller is dirty.

 

PF roller carefully with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the soft brush

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

CR movement

4. Check if the following

4. Replace the Printer

parts do not have any

mechanism with new

 

 

direction

damage.

one.

 

 

 

 

Spur gear 60

 

PF motor pinion

5. Replace the Printhead

 

with new one.

Troubleshooting