Stylus C40UX/C40SX/C20UX/C20SX

Revision A

Parameter

Minimum

Maximum

 

 

 

tsetup

500 ns

-

 

 

 

thold

500 ns

-

 

 

 

tstb

500 ns

-

 

 

 

tready

0

-

 

 

 

tbusy

-

500 ns

 

 

 

tt-out*

-

120 ns

 

 

 

tt-in**

-

200 ns

 

 

 

Parameter

Minimum

Maximum

 

 

 

treply

0

-

 

 

 

tack

500 ns

10 us

 

 

 

tnbusy

0

-

 

 

 

tnext

0

-

 

 

 

*Rise and fall time of every output signals

**Rise and fall time of every input signals

***Typical time of tack is shown below.

Parallel I/F mode

typical time of tack

 

 

High speed

2us

 

 

Normal speed

4usror

 

 

Connector pin assignment and signals :

Pin No.

Signal Name

GND pin

In/Out

Functional description

Return

 

 

 

 

 

 

 

 

 

1

-STROBE

19

In

The strobe pulse. Read-in of data is

performed at the falling edge of this pulse.

 

 

 

 

 

 

 

 

 

2

DATA0

20

In

The DATA0 through DATA7 signals

 

 

 

 

represent data bits 0 to 7, respectively.

3

DATA1

21

In

Each signal is at high level when data is

 

 

 

 

4

DATA2

22

In

logical 1 and low level when data is logical 0.

 

 

 

 

 

5

DATA3

23

In

 

 

 

 

 

 

6

DATA4

24

In

 

 

 

 

 

 

7

DATA5

25

In

 

 

 

 

 

 

8

DATA6

26

In

 

 

 

 

 

 

9

DATA7

27

In

 

 

 

 

 

 

10

-ACKNLG

28

Out

This signal is a negative pulse indicating that

the printer can again accept data.

 

 

 

 

Signal level : TTL compatible (IEEE-1284 level 1 device)

11

BUSY

29

Out

A high signal indicates that the printer cannot

Parameter

Minimum

Maximum

Condition

 

 

 

 

VOH*

-

5.5 V

 

 

 

 

 

is.

 

 

 

 

 

 

 

VOL*

-0.5 V

-

 

 

 

 

 

IOH*

-

0.32 mA

VOH = 2.4 V

 

 

 

 

IOL*

-

12 mA

VOL = 0.4 V

 

 

 

 

CO

-

50 pF

 

 

 

 

 

VIH

-

2.0 V

 

 

 

 

 

VIL

0.8V

-

 

 

 

 

 

IIH

-

0.32 mA

VIH = 2.0 V

 

 

 

 

IIL

-

12 mA

VIL = 0.8 V

 

 

 

 

CI

-

50 pF

 

 

 

 

 

*A low logic level on the Logic H signal is.

2.0 V or less when the printer is powered off and this signal is equal or exceeding 3.0V when the printer is powered on.

The receiver shall provide an impedance equivalent to 7.5 K ohm to ground

 

 

 

 

receive data.

 

 

 

 

 

12

PE

28

Out

A high signal indicates paper-out error.

 

 

 

 

 

13

SLCT

28

Out

Always at high level when the printer is

powered on.

 

 

 

 

 

 

 

 

 

14

-AFXT

30

In

Not used.

 

 

 

 

 

 

 

 

 

The falling edge of a negative pulse or a low

31

-INIT

30

In

signal on this line causes the printer to

 

 

 

 

initialize. Minimum 50 us pulse is necessary.

 

 

 

 

 

32

-ERROR

29

Out

A low signal indicates printer error condition.

 

 

 

 

 

36

-SLIN

30

In

Not used.

 

 

 

 

 

18

Logic H

-

Out

Pulled up to +5 V via 3.9 K ohm resistor.

 

 

 

 

 

35

+5V

-

Out

Pulled up to +5 V via 3.3 K ohm resistor.

PRODUCT DESCRIPTION

INTERFACE

14

Page 14
Image 14
Epson C40UX service manual Parameter Minimum Maximum, Parallel I/F mode Typical time of tack