Stylus C40UX/C40SX/C20UX/C20SX

Revision A

5.1.4 EEPROM initial setting

This function is used when replacing the MAIN board.

Using this function enables writing of the initial setting values to the new MAIN board’s EEPROM.

1.Choose the “EEPROM initial setting” in the Adjustment menu.

Figure 5-6. EEPROM initial setting

2.Click the “OK” button, then the initial setting values are written to the MAIN board.

5.1.5 Head ID

This adjustment function is required when any of the following parts is replaced.

†Printhead

†Main board

†Printer mechanism

This adjustment function enables you to write printhead Voltage ID into the specific address of the EEPROM. This operation is considered the most important to maintain proper ink discharging system. If any ID is not written correctly, it results in white or color lines and also gives bad influence on dot weight.

1.When replacing any of the parts above, make a note of VH voltage ID in advance. You can find the VH voltage ID on the following position:

„Printhead: On the top right face of the printhead.

A 6-digit ID code is printed with the QR code on the label.

„Printer mechanism: On the label of the packing box of the printer mechanism.

2.Run the Adjustment program and enter the Adjustment Main menu.

3.Choose the “Head ID” and click it. The menu shown in the next page appears.

Figure 5-7. Head ID input menu

Adjustment

Overview

80

Page 80
Image 80
Epson C40UX service manual Eeprom initial setting, Head ID