Epson MFJ-1278B manual Bbfailed, Digisent, Hovrerr, Hundrerr, Rcvdfrmr, Rcvdifra, Rcvdrej, Rcvdrnr

Models: MFJ-1278B

1 406
Download 406 pages 14.27 Kb
Page 217
Image 217

MFJ-1278B MULTI-MODE

OPERATIONAL COMMANDS

BBFAILED:

Counts number of times bbRAM checksum was in error.

DIGISENT:

Each frame digipeated by the MFJ-1278B causes the counter to increase.

HOVRERR:

Increases when HDLC receiver is not serviced rapidly enough and data is lost. This counter should never increment at any supported data rate.

HUNDRERR

Increases when the HDLC transmitter is not serviced rapidly enough and frames are aborted. This counter should never be non-zero at any supported data rate.

RCVDFRMR:

Increases when Frame reject frames are received from a connected station.

RCVDIFRA:

Increases for each reception of an I frame from a connectee.

RCVDREJ:

Increases for each reception of an REJect frame from a connectee.

RCVDRNR:

Counts the number of AX.25 L2 receiver- not-ready frames received since power-up and during connections. The count may be useful in gauging system throughput.

RCVDSABM:

Each received SABM frame addressed to the MFJ-1278B causes this counter to be increased by one.

RXABORT:

RXABORT is a count of the number of hardware-detected HDLC abort events. A large number of counts is perfectly normal and should not cause concern.

RXCOUNT:

Page 217
Image 217
Epson MFJ-1278B Bbfailed, Digisent, Hovrerr, Hundrerr, Rcvdfrmr, Rcvdifra, Rcvdrej, Rcvdrnr, Rcvdsabm, Rxabort, Rxcount