Epson MFJ-1278B manual CMDchr nnn 0=nn=255 Mode Pactor Default $03

Models: MFJ-1278B

1 406
Download 406 pages 14.27 Kb
Page 198
Image 198

MFJ-1278B MULTI-MODE

OPERATIONAL COMMANDS

Parameter:

nnnWhere the nnn variable equals 0 <=n<=255

The CHOChar command is used to designate the Pactor changeover character. This character initiates a control direction change in the Pactor signal.

This character can be varied from 0 to 255 decimal, for computers which may not support the default. The default is CTRL-Y. A value of 0 disables the Pactor changeover.

CMDchr nnn: 0<=nn<=255

Mode: Pactor

Default: $03

Parameters:

n<=nn<=255, specifying an ASCII character code.

The CMDchr command is used to designate the character which is used to change the COMMAND MODE entry character. You can enter the code in either hexadecimal or decimal form.

Command Mode is entered from CONVERSE Mode, when this character is typed. If you type the Command Mode entry character while you are in Command Mode, nothing will happen. This character must be entered before a disconnect can be issued, from either FEC calling mode or to issue a disconnect from a connected state.

The default character for the CMDCHR command is a <CTRL-C>.