STOP n

Mode: All

Default: $13

Parameters:

n0 - $7F, specifying an ASCII character code.

The STOP command selects the User Stop character, which is used to stop output from the MFJ-1278B to the terminal. You can enter the code in either hex or decimal. This is the character you will type to halt the MFJ-1278B's typing so that you can read text before it scrolls off your display.

Output is restarted with the User Restart character, which is set by the START command.

If the User Restart and User Stop characters are set to $00, software flow control to the MFJ-1278B is disabled, and the MFJ-1278B will only respond to hardware flow control (CTS).

If the same character is used for both the User Restart and User Stop characters the MFJ- 1278B will alternately start and stop transmission upon receipt of the character.