MFJ-1278B MULTI-MODE APPENDIX H COMMAND SUMMARY

Command

Paramete

Default

Mode

Function

Page

 

r

 

 

 

 

FEC

--

I-command

AMTOR

Initiates the broadcasting of Mode B

6-58

 

 

 

 

forward error correcting mode.

 

FIRMRNR

ONOFF

on

Packet

Controls the handling of busy states by

6-58

 

 

 

 

MFJ-1278.

 

FLOW

ONOFF

on

Packet

Sets type-in flow control to the terminal.

6-58

FLow

ON/OFF

on

Pactor

Performs the same as the packet flow

6-59

 

 

 

 

command.

 

FORWARD

--

I-command

Packet Mailbox

Mail forwading to the destination bbs.

6-59

FRACK

n

3

Packet

Sets the time interval between retries.

6-59

FULLDUP

ONOFF

off

Packet

Allows communication in full duplex.

6-60

GRAPHLF

ONOFF

off

FAX/SSTV

Adds an extra line feed in graphic

6-60

 

 

 

 

printing to the printer.

 

HEADERLN

ONOFF

off

Packet

Affects the display format of monitored

6-61

 

 

 

 

packets.

 

HEALLED

ONOFF

off

Packet

Redefines the function of the STA and

6-61

 

 

 

 

CON LEDs.

 

HID

ONOFF

off

Packet

Controls the sending of identification

6-62

 

 

 

 

packets by the MFJ-1278B.

 

ID

--

I-command

AMTOR

Sends a keyed modulated CW ID of your

6-62

 

 

 

 

station in AMTOR.

 

ID

--

I-command

Packet

Sends a special identification packet to be

6-62

 

 

 

 

sent in packet.

 

Id

--

I-command

Pactor

Initiates an immediate CWID to be sent.

6-63

IDTime

nnn

590

Pactor

Specifies the CWID time interval in the

6-63

 

 

 

 

Pactor mode.

 

K

---

I-command

Pactor

Puts the MFJ-1278B into CONVERSE

6-63

 

 

 

 

mode while in Pactor mode.

 

KILONFWD

ONOFF

off

M-Packet

Determines whether or not the MFJ-

6-63

 

 

 

 

1278B deletes a message after it has been

 

 

 

 

 

forwarded.

 

KISS

ONOFF

off

Packet

Allows the MFJ-1278B to works as a

6-64

 

 

 

 

modem for special programs such as

 

 

 

 

 

TCP/IP.

 

Lc

--

I-command

Pactor

Initiates a LongPath connect in the Pactor

6-65

 

 

 

 

mode.

 

LCALLS

call

none

Packet

Used in conjunction with BUDLIST,

6-65

 

 

 

 

allows selective monitoring of other

 

 

 

 

 

packets.

 

LCSTREAM

ONOFF

on

Packet

Allows the MFJ-1278B to understand

6-66

 

 

 

 

lower case characters as upper case after

 

 

 

 

 

the streamswitch is entered.

 

LCOK

ONOFF

on

Packet

Determines whether the lower or upper

6-66

 

 

 

 

case characters are set.

 

LEDmode

0/1

1

Pactor

Rapid flashing of STA and CON leds for

6-67

 

 

 

 

the 200 baud Pactor mode.

 

LFadd

ON/OFF

off

Pactor

Appends LF after a received carriage

6-67

 

 

 

 

return.

 

Page 364
Image 364
Epson MFJ-1278B manual Fec