EPSON | Rev. A |
4.2.21.3 Fusing Roller Thermistor / Thermostat / Temperature Fuse Removal
1.Remove the Fuser Unit. (See Section 4.2.21.1.)
2.Release the joint for the Fuser Unit Cover and the Fusing Roller Heater Lamp Front Cover.
3.Remove one screw (3501) securing the Fusing Roller Heater Lamp Front Cover to the Fuser Unit Frame Assembly, and remove the Fusing Roller Heater Lamp Front Cover. (See Section 4.2.21.2.)
4.Remove one
Figure 4-40. Lever Removal
5.Release the thermistor harness and paper eject sensor harness from the clamps in the Fusing Roller Heater Lamp Rear Cover.
6.Remove one screw (3501) securing the Fusing Roller Heater Lamp Rear Cover to the User Unit Frame Assembly, and remove the Fusing Roller Lamp rear Cover.
Figure 4-41. Fusing Roller Heater lamp Rear Cover Removal
7.Remove two screws (1305) securing the Fusing Roller Heater Lamp Holder to the Fuser Unit Frame Assembly, and remove the Fusing Roller Heater Lamp Holder.
8.Pull out the Heater Lamp.
Figure 4-42. Fusing Roller Heater Lamp Holder Removal
Chapter 4 Disassembly/Assembly | 115 |