EPSON | Rev. A |
4.2.4.5 Timing Roller Removal
1.Remove the Transfer Unit. (See Section 4.2.4.2.)
2.Put up the transfer front guide plate. (See Section 4.2.4.1.)
3.Remove the Timing Clutch. (See Section 4.2.4.4.)
4.Release the hook securing the Guide Bar to the Holder Assembly and remove the paper dust remove filter from the Holder Assembly.
5.Remove two tension springs securing the bushing for the Timing Driven Roller to the Holder Assembly.
6.Remove two
7.Remove
Figure 4-14. Timing Roller Removal
Chapter 4 Disassembly/Assembly | 98 |