| Revision A |
1.4.5.2 List of Data Controlled by the Engine Status Sheet and Controlling Method
Table
Data name | Storage location |
| Storage location | Count condition | Clear condition |
| |||||
|
|
|
|
| |
Total Counts | Mechanical controller | to 600,000 sheets | During printing | EJL (EEPROM initialization) | |
|
|
|
|
| |
Jam Counts | Controller | to 100,000 sheets | When a jam occurs | (EEPROM Initialization) | |
|
|
|
|
|
|
Toner | Controller | 0 | - 100% | During printing | New one detected (EEPROM initialization) |
OPC Counter | Mechanical controller |
|
| During printing | None |
Cartridge Change | Controller | 0 | - 100 times | New one detected | (EEPROM initialization) |
|
|
|
|
| |
Fuser Counter | Controller | to 600,000 sheets | During printing | Panel, (EEPROM) | |
Fuser Change | Controller | 0 | - 10 times | Panel | (EEPROM initialization) |
|
|
|
|
| |
MP Counter | Controller | to 600,000 sheets | During a paper feed | Panel, (EEPROM initialization) | |
LC1 Counter | Controller | to 600,000 sheets | During a paper feed | Panel, (EEPROM initialization) | |
LC2 Counter | Controller | to 600,000 sheets | During a paper feed | Panel, (EEPROM initialization) | |
LC3 Counter | Controller | to 600,000 sheets | During a paper feed | Panel, (EEPROM initialization) | |
MP FR Change | Controller | 0 | - 10 times | Panel | (EEPROM initialization) |
LC1 FR Change | Controller | 0 | - 10 times | panel | (EEPROM initialization) |
LC2 FR Change | Controller | 0 | - 10 times | Panel | (EEPROM initialization) |
LC3 FR Change | Controller | 0 | - 10 times | Panel | (EEPROM initialization) |
|
|
|
|
| |
TR Counter | Controller | to 600,000 sheets | During printing |
| |
TR Change | Controller | 0 | - 10 times | Panel |
|
|
|
|
|
|
|
Error Code1 | Controller |
|
| When an error occurs | Panel, (EEPROM initialization) |
Error Page 1 | Controller |
|
| When an error occurs | Panel, (EEPROM initialization) |
: |
|
|
| When an error occurs |
|
Error Code 20 | Controller |
|
| When an error occurs | Panel, (EEPROM initialization) |
Error Page 20 | Controller |
|
| When an error occurs | Panel, (EEPROM initialization) |
|
|
|
|
|
|
NOTE:“Panel” in the “Clear condition” column means the value can be cleared by the Maintenance Mode.
NOTE:When the value controlled by the controller reaches the maximum, it does not increase any more.
Product Description | Panel Operation | 47 |