EPL-N2700

Revision A

1.2.9 Electrical Specifications

AC LINE NOISE

Pulse width:

50 to 1000 ns

Pulse polarity:

+ / -

Repetition:

Asynchronous

￿Modes:

Common / Normal

Voltage:

1KV

 

(Parts must be able to withstand 2KV without

 

damage)

TRANSIENT OUTAGE

DIP 100% (at rated voltage - 10%) 1 cycle (No abnormal print quality)

ELECTROSTATIC TOLERANCE

Up to 10KV:

No hard error, no user-nonrecoverable

￿

software error

Up to 15KV:

No damage to parts

SURGE CURRENT

1/2-cycle / Not above 50A

INSULATION RESISTANCE

10M Ω or more

DIELECTRIC STRENGTH

Insulation shall not break down when the following voltage is applied between primary circuit and chassis for 1 minute:

￿100V version:

AC1000V

200V version:

AC1500V

LEAKAGE CURRENT

3.5mA or less