(3)Rewriting specified area

An entire specified area is rewritten with specified data.

(4)Copying specified area

The content of a specified area is copied to another area.

(5)Monitoring memory

Four memory locations, each with area to store 4 consecutive words, can be registered as watch data addresses. The registered watch data can be verified in the [Register] window. The content of this window is updated in real time at 0.5-second intervals by the on-the-fly function. Addresses 0, 4, 8, and C are made the watch data addresses by default.

CHAPTER 8: DEBUGGER

The memory content displayed at the left indicates data at a specified address, and the one displayed at the right indicates 4-word data at the high-order address.

Monitor data
Operating registersThe following operations can be performed on registers:Table 8.8.3.3 Commands/menu items to operate registers

Function

Command

Menu

Displaying registers

rd

[View Register]

Modifying register values

rs

(1)Displaying registersRegister contents can be displayed in the [Register] or [Command] window.Registers: PC, A, B, X and [X], Y and [Y], F, SP1, SP2, EXT, and QUEUE

While the program is being executed, the PC address and F register are updated in real time every 0.5 seconds by the on-the-fly function.

(2)Modifying register values

The contents of the above registers can be set to any desired value. The register values can be directly modified on the [Register] window.

Displaying option data

Option data in the ICE option areas (function option data, segment option data, or melody data). Data is displayed in the [Command] window in hexadecimal dump format.

Table 8.8.3.4 Command to display option data

FunctionCommand

Displaying option data

od

S5U1C63000A MANUAL

EPSON

145