CHAPTER 7: DISASSEMBLER

7.4 Messages

The disassembler delivers all its messages via the Standard Output (stdout).

Start-up message

The disassembler outputs the following message when it starts up.

Disassembler 63 Ver x.xx

Copyright (C) SEIKO EPSON CORP. 1998-2001

End message

The disassembler outputs the following messages to indicate which files have been created when it ends normally.

Created preprocessed source file <FILE NAME>.MS

Created error log file DS63.ERR

Disassembly 0 error(s) 0 warning(s)

Usage output

If no file name was specified or an option was not specified correctly, the disassembler ends after delivering the following message concerning the usage:

Usage: ds63

[options] <file

name>

 

Options: -cl

Use

lower case

characters

-cu

Use

upper case

characters

-e

Output error log file (DS63.ERR)

-o

<file name> Specify output

file name

File names:

Absolute object

file (.ABS

or .CSA/.LSA/.HSA)

When error/warning occurs

If an error occurs, an error message will appear before the end message shows up.

Example:

Error: Cannot open file TEST.ABS

Disassembly 1 error(s) 0 warning(s)

In the case of an error, the disassembler ends without creating an output file.

If a warning is issued, a warning message will appear before the end message shows up.

Example:

Warning: Input file name extension .HSA conflict

Disassembly 0 error(s) 1 warning(s)

In the case of a warning, the disassembler ends after creating an output file.

For details on errors and warnings, refer to Section 7.6 "Error/Warning Messages".

S5U1C63000A MANUAL

EPSON

113

(S1C63 FAMILY ASSEMBLER PACKAGE)