CHAPTER 8: DEBUGGER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format

 

 

 

 

 

 

 

 

 

(1) >md <option> <num> [ ... <option> <num>]

(direct input mode)

 

(2) >md

 

 

 

 

 

(guidance mode)

 

 

Current settings

 

 

 

 

 

 

 

 

 

 

On the fly interval0 - 5 times/sec

 

...? Current setting : <0 ... 5>

 

 

Counter unit

 

1. time2. cycle

 

...? Current setting : <1 2>

 

 

Interrupt at step

 

1. allowed2. not allowed ...? Current setting : <1 2>

 

 

Step display mode1. each2. last

 

...? Current setting : <1 2>

 

 

Counter mode

 

1. reset2. hold

 

...? Current setting : <1 2>

 

 

Illegal instruction1. check2. no check

...? Current setting : <1 2>

 

 

Cmw wait time

 

1 - 256 s

 

 

...? Current setting : <1 ... 256>

 

>

 

 

 

 

 

 

 

 

 

 

 

 

<option>:

 

 

<num>:

 

 

 

 

 

 

-f (on the fly interval)

0–5 times/sec

 

 

 

 

 

 

-u (couter unit)

 

 

1. Time

2. Cycle

 

 

 

 

-i (interrupt at step)

 

1. Allowed

2. Not allowed

 

 

 

 

-s (step display mode)

1. Each

2. Last

 

 

 

 

 

-c (counter mode)

 

1. Reset

2. Hold

 

 

 

 

 

-il (illegal instruction)

1. Check

2. No check

 

 

 

 

-cm (cmw wait time)

1–256 sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Examples

 

 

 

 

 

 

 

 

 

 

>md -u 1

...Sets the execution cycle counter in time measurement mode.

 

 

>md

 

 

 

 

 

 

 

 

 

 

On the fly interval

: 2 times/sec

 

 

 

 

 

Counter unit

 

 

: time

 

 

 

 

 

 

Interrupt at step

: not allowed

 

 

 

 

 

Step display mode

: each

 

 

 

 

 

 

Counter mode

 

 

: hold

 

 

 

 

 

 

Illegal instruction

: check

 

 

 

 

 

 

Cmw wait time

 

: 1 s

 

 

 

 

 

 

On the fly interval

0 - 5 times/sec

 

...? 2 times/sec : 5

 

Counter unit

 

 

1.time

2.cycle

...? time

: 2

 

Interrupt at step

1.allowed

2.not allowed ...? not allowed : 1

 

Step display mode

1.each

2.last

...? each

: 2

 

Counter mode

 

 

1.reset

2.hold

...? hold

:

 

Illegal instruction

1.check

2.no check

...? check

:

 

Cmw wait time

 

1 - 256 s

 

 

...?

1

s : 3

>

Notes

The actual interval of the on-the-fly display is obtained from the expression below.

(1 [sec] / Count set) + (Overhead of the PC, RS232C interface and ICE [sec]) = display interval [sec] The overhead varies depending on the performance of the PC and baud rate of the RS232C interface. Be aware that there is a 0.05 sec to 0.1 sec overhead in this system.

In guidance mode, the following keyboard inputs have special meaning:

"q↵ " … Command is terminated. (finish inputting and start execution)

"^↵ " … Return to previous item.

"↵ " … Input is skipped. (keep current value)

230

EPSON

S5U1C63000A MANUAL

 

 

(S1C63 FAMILY ASSEMBLER PACKAGE)