CHAPTER 10: SEGMENT OPTION GENERATOR

10.3.4 Option Selection Buttons

The following buttons are available in the option setup area.

OUTPUT Option buttons

These buttons select SEG pin output modes. These buttons are enabled when you click a SPEC cell in

[SEGMENT DECODE TABLE].

Selects LCD segment output.

Selects DC-complementary output.

Selects DC-Pch open-drain output.

Selects DC-Nch open-drain output.

Selects segment/common shared output.

[Delete] button

Clears one selected segment assignment.

10.3.5 Operation Procedure

The following shows the basic operation procedure.

(1) Loading the device information definition file

First, select a device information definition file (s1c63xxx.ini) and load it.

Select [Device INI Select] from the [Tool] menu or click the [Device INI Select] button.

[Device INI Select] button

The dialog box shown below appears. Enter a file name including the path in the text box or select a file by clicking the [Ref] button.

Click [OK], and the file is loaded. If the specified file exists and there is no problem with its contents, the set-up items in winsog are initialized with the loaded device information.

To stop loading the file, click [Cancel].

254

EPSON

S5U1C63000A MANUAL

 

 

(S1C63 FAMILY ASSEMBLER PACKAGE)