CHAPTER 10: SEGMENT OPTION GENERATOR

(6) Setting unused SEG pins

For SEG pins that are used for neither LCD output nor DC output, leave COM0 through COM3 cells in [SEGMENT DECODE TABLE] blank. However, SPEC cells cannot be left blank, so select segment output (S) for the corresponding SPEC cells.

Selection example:

(7) Creating files

After selecting options, select [Generate] from the [Tool] menu or click the [Generate] button to create the files.

[Generate] button

The segment option document file you specified from the [Setup] dialog box and the segment option HEX file (if specified) are created. When winsog has finished creating the files normally, it displays the message "Making file(s) is completed" in the message area. If an error occurs, an error message is displayed.

(8) Saving uncompleted segment option data

You can save the segment option settings that have not been completed as a segment assignment data file. To save data, select [Record - Save] from the [File] menu or click the [Save] button.

[Save] button

The dialog box shown below appears, so enter a file name including the path in the text box or select a file by clicking the [Ref] button.

Clicking [OK] saves the current assignment data to the specified file. To stop saving, click [Cancel].

You can read an existing segment option document file into winsog and correct it as necessary.

To load a segment assignment data file, select [Record - Load] from the [File] menu or click the [Load] button.

[Load] button

The dialog box shown below appears, so enter a file name including the path in the text box or select a file by clicking the [Ref] button.

Click [OK], and the file is loaded. If the specified file exists and there is no problem with its contents, the option setup area is updated according to the segment assignment data saved in the file. You can continue segment assignment from the previous set state. To stop loading the file, click [Cancel].

258

EPSON

S5U1C63000A MANUAL

 

 

(S1C63 FAMILY ASSEMBLER PACKAGE)