CHAPTER 8: DEBUGGER

8.3.3 Start-up Messages

When the debugger starts up, it outputs the following message in the [Command] window. (Refer to the next section for details about windows.)

Debugger63 Ver x.xx Copyright SEIKO EPSON CORP. 1998-2001

Connecting COMx with xxxxx

baud rate ... done

Parameter

file name

:

xxxxxxxx.par

 

Version

:

xx

 

Chip name :

63xxx

CPU version

:

x.x

PRC board

version

:

x.x

LCD board

version

:

x.x

EXT board

version

:

x.x

ICE hardware version

:

x.x

ICE software version

:

x.x

DIAG test

 

:

omitted

Map...............................

 

done

Initialize

........................

done

>

 

 

 

8.3.4 Hardware Check at Start-up

When the debugger is invoked, it first performs the tests and initializing operations described below.

(1)Testing connection of the ICE

Debugger db63 first checks to see that the ICE is connected to your system and that communication is possible without any problems. The following message is displayed in the [Command] window.

During test

Connecting COMx with xxxxx baud rate ...

When terminated normally

Connecting COMx with xxxxx baud rate ... done

When an error is encountered

Connecting COMx with xxxxx baud rate ... failure <error message>

The error message indicates that communication between the personal computer and the ICE is not functioning properly. In this case, to verify the following:

A standard RS-232C cable is used

The COM port is correct

The baud rates on both sides are matched

The PRC board is correctly fitted in place

The ICE's power is turned on

The ICE remains reset

For the causes of errors, refer to Section 8.10, "Status/Error/Warning Messages".

S5U1C63000A MANUAL

EPSON

121

(S1C63 FAMILY ASSEMBLER PACKAGE)