CHAPTER 8: DEBUGGER

(4)During log mode

If the program is single-stepped after turning on the log mode, the same contents as when executing the rd command are displayed in the [Command] window after each step is completed.

Notes

The step count must be specified within the range of 0 to 65,535. An error results if the limit is ex- ceeded.

Error : Number of steps out of range, use 0-65535

If the [Data] window is opened, its display contents are updated after the execution.

During a single-step operation, the program will not break even if the break condition set by a command is met.

Unlike in successive executions (g or gr command), the [Register] window is updated every time a step is executed.

GUI utility

[Run Step] menu item, [Step] button

When this menu item or button is selected, the s command without step count is executed.

[Step] button

S5U1C63000A MANUAL

EPSON

181

(S1C63 FAMILY ASSEMBLER PACKAGE)