Chapter 2

Table 2.1 Supply Cord Wiring Colors

 

UK

EUROPE

USA

 

(BS 1363)

(CEE 7/7)

(NEMA 5-15P)

 

 

 

 

Earth:

Green-and-yellow

Green-and-yellow

Green

 

 

 

 

Neutral:

Blue

Blue

White

 

 

 

 

Live:

Brown

Brown

Black

 

 

 

 

If the colors do not correspond with the colored markings identifying the terminals in a locally supplied plug, proceed as in Annex B. The inclusion of Table 2.2 is for reference.

Table 2.2 Non Standard Supply Cord Wire Colors

Wire Color (UK)

Action

 

 

green-and-yellow

...must be connected to the terminal in the plug which is marked

 

with the letter E or the safety earth symbol or colored green or

 

green-and-yellow.

 

 

blue

...must be connected to the terminal in the plug which is marked

 

with the letter N or colored black.

 

 

brown

...must be connected to the terminal in the plug which is marked

 

with the letter L or colored red.

 

 

2.5.3Connecting the Equipment to the AC Power Supply

As there is no mains power switch fitted to this unit, ensure the local AC power supply is switched OFF before connecting the supply cord. Connect the mains lead to the equipment and then to the local supply.

2.6Protective Earth/Technical Earth

Warnings!

This unit must be correctly earthed through the molded plug supplied; if the local mains supply does not have an earth conductor do not connect the unit. Contact Ericsson Customer Services for advice.

Before connecting the unit to the supply, check the supply requirements in Annex B.

The terminal marked at the rear panel is a Technical Earth. Its use is recommended. This is NOT a protective earth for electric shock protection. The terminal is provided to:

1.Ensure all equipment chassis fixed within a rack are at the same technical earth potential.