Page 132
Image 132
17 Appendix
17.1.4.Thermocouple T type input
Accuracy: Slope at 0
C = 40
V/
C
17.1.5.Thermocouple S type input
Accuracy: Slope at 500
C = 10
V/
C
Page 3
Page 131
Page 133
Page 132
Image 132
Page 131
Page 133
Contents
Recorders
Page
Page
Page
Garanty
Page
Contents
Diagrams
Inputs / Outputs
Appendix
Page
Symbols and definitions
Important Information
Security instructions
Important informations
Symbols that appear in this manual
Symbols that appear on the appliance
See chapter Technical specifications
Conformity and restrictions of the appliance
Presentation
Presentation
Presentation
Rear side or top side
Escort 3016B and Escort 3004B
Front side
Description of the screen
Keys
Thumb Wheel
Updating the Internal Software
F1 Modify
Initialisation and Precautions of USE
Initialisation
Initialisation Storage precautions of the records
Fuse
Initialisation Power up of Escort 3008B
Configuration on POWER-UP
Initialisation Power up of Escort 3016B and Escort 3004B
Measure of temperature with a thermocouple
Measure of temperature with a PT100
Measure of voltage
Measure of intensity
Connection of the grounding
Routine maintenance
Calibration of the offsets
Unplug the appliance before any intervention
Menu key Calibration Offset
Factory adjustement
Menu key Reload Factory Coeff
Initialisation and precautions of use
Mode key
Use
Help key
Set up key
Use
Chart key
Escort 3008B recorder only
Channels set up key
Analogical channels
Use
Use Logic channels
Channel on/off key
Display Ft oscilloscope mode
Display key
Vertical or horizontal sweep on screen
Use
Direction keys
Use Display XY
Y channel
Digital display
Trigger key
Replay key
Blocks and Files
Start/Stop key
Paper-feed key
Diagrams
Diagrams
Positions of the channels
Change diagrams
Triggers
Triggers
Trigger key, parameters Start and Stop
Single / Several thresholds
Triggering with analogical channels
Single threshold
Triggers Several thresholds
Triggers Trigger according to thresholds
Triggers Trigger according to the slope
Triggering with logical channels
Mathematical Calculations
Definitions
Mathematical calculations
Types of calculations
Minimum
Maximum
Low
High
Width
V
Cyclical RMS
Direct Mode
Configuration of the plotting
Direct mode
Direct mode
Triggering plotting
Direct mode
Rearmament of the plotting
Writing data
Example of plotting program
Channels set up key
Memory Mode
Configuration Triggering of the acquisition
Memory mode
Sampling period
Manual with the F2 key Urge triggering
Trigger
Internal memory, blocks
Triggering position
Double Trigger mode
Recording
Memory mode
Memory mode
Memory output
Memory mode
10. GO/NOGO Mode
Configuration and triggering of the acquisition
10 Go/Nogo mode
Memory Mode
Creation of the frame
10 Go/Nogo mode
Use of the frame
Channels for Go/Nogo selected in the Trigger
File Mode
Configuration and start of the acquisition
File mode
Limits
Binary file
Ascii file
File mode
File Management
General
File management
Management of the configuration files
Saving the configuration files
File management Loading the configuration files
Management of the acquisition files
Press the Load from disk key
Saving the acquisitions
Real time
PC Software for Analysis
File management Loading the acquisition files
File management File transfer with FTP
File management Display with Escortview
File management
ESCORTview Myfile.rec /x
Plot set up and launch
Replay , key Setup Plot
Printing with Escort 3016B and Escort 3004B
Printing
Printing
Printer Setup
Printing
Supplementary input / output connector
Inputs / Outputs
Inputs / Outputs
Pin no Input or Ouput
Logical inputs
13.1.1.Use
Plotting and display
External clock
Alarm outputs
Power supply output
Keyboard input
13.1.2.Use
Mouse input
XGA screen output
14.8. RS232
Not used. Reserved to future applications
USB Interface
Ethernet RJ45 interface
Ethernet Interface
Interface Ethernet
Ethernet interface
Programming language
Format of the reception messages
Syntax of a reception message
Syntax of a message unit
Data
Ethernet interface Format of the emission messages
Standard instructions
Text data
Indication of the status of the appliance
Structure of the status data
Registers of service request
Status register
Validation register
Registers of standard events
Register of the alarms
Using the structure of status data
Example
Setup
Programming dictionary
Ethernet interface Parameters of the channels
CHAnnel
Changing mode
Functions of the channels and between the channels
Current function
Ethernet interface Chart
Header Parameters Examples Directplot
Triggerings
Starttrig
Ethernet interface Triggers
Header Parameters Examples Triglog P1
Reloadings, real-time savings
MEMSpeed
Ethernet interface Launching plotting and recording
RECord
Ethernet interface Direct display
Replay memory output
Error messages
Ethernet interface Service request
Ethernet interface
Technical Specifications
Isolated inputs
Technical specifications Temperature recording
Sampling
Bandwidth
Multiplexed inputs
Type of measurements
Supplementary inputs / outputs
Calibre
Alarm outputs
External power supply
Paper
Display
File acquisition
Communication interface
Miscellaneous
Environmental conditions Escort 3008B
Technical specifications Dimensions, weight
Environmental conditions Escort 3016B & Escort 3004B
Electromagnetic compatibility
Accordance test
Internal saving battery
Accessory items
16.13.2 Optional accessory items
Items furnished with the appliance
16.13.3 Expandable items
Appendix
Information about the ranges of the inputs
Appendix
Voltage-type inputs
Appendix Thermocouple J type input
Thermocouple K type input
Appendix Thermocouple T type input
Thermocouple S type input
Appendix Thermocouple B type input
Thermocouple E type input
Appendix Thermocouple N type input
Thermocouple W5 type input
Accuracy of the thermocouple measurements
Example of Accuracy Calculation
Temperature C
Accuracy of the PT100 measurements
Slope V/ C
Accuracy class index of class
Top
Page
Image
Contents