5-10 IPI 100 Series, IPI 200 Series • Programming and Control

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional

 

(host to intercom)

(host to intercom)

(intercom to host)

description

 

 

 

 

 

Status commands

 

 

 

 

View all voltage

11S

11S

responses from commands

 

and

 

 

12S•13S•14S•15S•16S•20S ]

temperature

 

 

 

 

status

 

 

 

 

View +12 V

12S

12S

+X20^]

 

power supply

 

 

 

 

voltage

 

 

 

 

View +5 V IR

13S

13S

+X20^]

 

receiver port

 

 

 

 

voltage

 

 

 

 

View +3.3 V

14S

14S

+X20^]

 

IP Link/FPGA

 

 

 

 

voltage

 

 

 

 

View +1.5 V

15S

15S

+X20^]

 

FPGA voltage

 

 

 

 

View internal

20S

20S

X20&]

 

temperature

 

 

 

 

status

 

 

 

 

Firmware version, part number & information requests

NIn a query response, an asterisk (*) after the version number indicates the version that is currently used.

A question mark (? or ?.??) indicates that the factory default firmware is the only firmware loaded in the IPI.

A carat (^) indicates the version of firmware that should be running, but, since a mode 1 reset was performed, the factory default firmware version is loaded and running instead.

An exclamation point (!) indicates that the firmware is corrupted.

IPI 201/204 SISProgramming, cont’d

Page 68
Image 68
Extron electronic IPI 200 Series, IPI 100 Series manual +X20, Status commands