General

Power

Supplied by MLC 226 IP

Power input requirements

+12 VDC, <100 mA

Distance between MLC 226 IP and IP

 

100’ (30.5 m), maximum

Connection types

RJ-45 jacks with CAT 5, CAT 5e, or CAT 6

 

cable

Temperature/humidity

Storage: -40 to +158 °F (-40 to +70 °C) /

 

10% to 90%, noncondensing

 

Operating: +32 to +122 °F (0 to +50 °C) /

 

10% to 90%, noncondensing

Mounting

 

Rack mount

Yes, with optional faceplate

Furniture mount

Also furniture- and wall-mountable

 

with optional faceplate or in an

 

MLC 226 IP AAP faceplate

Enclosure type

Metal faceplate

Enclosure dimensions

 

Board/device

2.7" H x 2.6" W x 0.9" D

 

(6.9 cm H x 6.6 cm W x 2.3 cm D)

 

(Depth excludes buttons and switch.

 

Allow at least 2.1" (5.3 cm) depth in the

 

wall or furniture.)

Product weight

0.2 lbs (0.1 kg)

Shipping weight

1 lb (1 kg)

Vibration

ISTA 1A in carton (International Safe

 

Transit Association)

Regulatory Compliance

 

Safety

CE, CUL, UL

Compliances

CE, C-tick, FCC Class A, ICES, VCCI

MTBF

30,000 hours

Warranty

3 years parts and labor

NAll nominal levels are at ±10%.

NSpecifications are subject to change without notice.

(7.52-050307-D5)

IPI 100 Series, IPI 200 Series • Specifications, Accessories

A-3

Page 93