IPI 100 Series, IPI 200 Series • Programming and Control
IPI 201/204 SIS Programming, cont’d

5-20

Command ASCII (Telnet)
(host to intercom)
URL Encoded (Web)
(host to intercom)
Response
(intercom to host)

Additional

description
Read verbose
mode status
E CV }WCV| X2@ ]
Set the broadcast
mode24
E X6$,X1$ EB }W X6$%2C X1$ EB|Bmd X6$,X1$ ]This command details how
often and to what subnet
work the IPI broadcasts a
message.
X6$ = Broadcast repetition
interval in seconds (0 to 255
[4.25 minutes], default = 0 =
off).
X1$ = IP address (xxx.xxx.
xxx.xxx). Leading zeros
in each of four elds are
optional in setting values,
and they are suppressed in
returned values.
Default broadcast address:
255.255.255.255.
Set the broadcast
mode to the
default address24
E X6$ EB }W X6$ EB|Bmd
X6$,255.255.255.255]
Clear the
broadcast mode24
E 0 EB }W 0 EB|Bmd 000,255.255.255.255]This command sets the repeat
interval to zero, turning off
the broadcast mode.
View the
broadcast mode
E EB }W EB| X6$,X1$ ]