IPI 100 Series, IPI 200 Series • Programming and Control
IPI 201/204 SIS Programming, cont’d
5-12
Command ASCII (Telnet)
(host to intercom)
URL Encoded (Web)
(host to intercom)
Response
(intercom to host)
Additional
description
Query factory
rmware version
3Q 3Q X1!
(kernel version–model description–date time of
upload)]
or Ver03*X1!
(kernel version–model description–date time
of upload)]
Factory-installed rmware is
different from the bootstrap
rmware, but it is also
not user-replaceable. This
rmware was installed at the
factory; it is the version the
controller reverts to after a
mode 1 reset (see chpt. 2).
Example: 3Q 3Q 1.00(1.18-IPI 201/IPI 201/IPI 204 -Thu, 20 Jan 2005 09:41:47
GMT) ]
In this example the factory
rmware version
is 1.00 and the IP Link kernel
version is 1.18 for the IPI204,
dated 20 January 2005.