Schematic Diagrams 8

VCC

Q1

P1

P 2

2

7

12

17

39DS2

HLMP - 1402 - 101

R11

360

R1

10K

R13

SI9405DY

2 S D 8

37

6

4G 5

R17

R9

C9

C6

1.0

.1

47K

47K

35V

25V

CVPP

18

VPP1

CVCC

5 2

VPP2

17

VCC

51VCC

CRESET 5 8

RESET

6 6

D10

 

C 5

 

20

47

 

10V

DS1

21

 

 

 

24

HLMP - 1302 - 101

 

27

 

30

 

33

 

36

 

40

 

28D8

32D9

34D10

38D11

29D12

31D13

35D14

37D15

26A1

22A2

25A3

23 A4

9 XMCARD*

6XRDU*

4XWRU*

14DTACK*

11MCINT*

19 XSCLK

R15

 

 

 

 

 

33

 

 

XC1736 - DS08C

 

6

CEO

CE

4

1

D

R/OE

3

 

 

CLK

2

 

U 3

 

 

P 3

VCC

 

 

 

R 8

 

 

1

 

 

 

 

 

2

10K

 

 

3

 

 

 

 

 

4

CCLK

 

 

5

D/P*

 

 

6

DIN

16 RESET*

R10

360

 

 

25

24

3 6

D0

BUSYLED

BATTLED

3 3

 

 

3 5

D1

 

 

3 9

D2

 

 

D3

 

 

4 3

D4

 

 

4 5

D5

 

 

4 8

D6

 

 

4 7

D7

 

 

3 4

A1

 

 

3 8

A2

 

 

4 4

A3

 

 

4 0

A4

 

 

4 9

CS

 

 

5 0

R D

 

 

51W R

5 8

DTACK

6 0

IRQ

3 0

SCLK

100DIN

8 0

D/P

7 8

RESET

2CCLK

M 0

M1 M 2

54

52

56

R 6

360

1.5K

 

VCC

 

 

 

 

26

29

61

96

22

18

VCC_SEL0

P W R D W N

CRESET

CD2

C W P

ALM1

2635A PCMCIA INTERFACE

U1

XC3030A - 7PQ100C

CEL

C R D

C W R

CWAIT

CP1

CP0

CD3

CD4

CD5

CD6

CD7

62

63

64

17

21

19

93

90

88

85

86

 

 

Z2

 

 

Z2

 

 

Z2

20

97

95

ALM2

CD1

CD0

 

 

CA0

 

 

CA1

 

 

CA2

 

 

CA3

 

 

REG

 

 

CA4

 

 

CA5

 

 

CA6

 

 

CA25

 

 

CA7

 

 

CA24

 

 

CA12

 

 

CA23

 

 

CA15

 

 

CA22

 

 

CA16

 

 

CA21

 

 

CA20

 

 

CA19

 

 

CA14

 

 

CRDY

 

 

CA18

 

 

CA13

 

 

CA17

CA10

CA11

CA8

CA9

67

70

73

Z2

Z2

Z2

Z2

Z2

107

100

98

11 6

14

15

6

13

8

12

11

9

5

10

98

94

92

84

87

89

74

8 3

71

82

23

69

75

68

72

100

152

161

14 3

134

125

R16

47K

R12

47K

R14 R2 R7 R 5

47K 47K 47K 47K

C D < 2 >

3 2

D2

W P

6 5

D9

3 3

W P

BVD1

6 3

BVD1

BVD2

6 2

BVD2

C D < 1 >

31

D1

C D < 0 >

6 4

D8

3 0

D0

 

4 4

RFU1

 

4 5

RFU2

 

5 7

RFU3

 

6 0

RFU4

C A < 0 >

4 3

RFSH

2 9

A0

C A < 1 >

2 8

A1

C A < 2 >

2 7

A2

C A < 3 >

2 6

A3

REG*

61

REG

C A < 4 >

2 5

A4

C A < 5 >

2 4

A5

C A < 6 >

2 3

A6

C A < 2 5 >

5 6

A25

C A < 7 >

2 2

A7

C A < 2 4 >

5 5

A24

CA<12>

21

A12

C A < 2 3 >

5 4

A23

CA<15>

2 0

A15

C A < 2 2 >

5 3

A22

CA<16>

19

A16

CA<21>

5 0

A21

C A < 2 0 >

4 9

A20

CA<19>

4 8

A19

CA<14>

14

A14

RDY/BSY

16

RDY/BSY

CA<18>

4 7

A18

CA<13>

13

A13

CA<17>

4 6

A17

C A < 8 >

12

A8

 

1

G N D

 

3 4

G N D

 

3 5

G N D

 

6 8

G N D

 

6 9

EARTH

 

7 0

EARTH

C A < 9 >

11

A9

CA<11>

10

A11

CA<10>

8

A10

 

41

D15

C D < 7 >

4 0

D14

6

D7

C D < 6 >

3 9

D13

5

D6

C D < 5 >

3 8

D12

4

D5

C D < 4 >

3 7

D11

3

D4

C D < 3 >

2

D3

CD1

3 6

CD1

CD2

6 7

CD2

CWAIT*

5 9

WAIT

CWR*

15

W E

NOTES; UNLESS OTHERWISE SPECIFIED

1.ALL CAPACITOR VALUES ARE IN MICROFARADS.

2.ALL RESISTOR VALUES ARE IN OHMS.

3.ALL RESISTOR ARE 1/8W,5%.

4.THIS DRAWING IS ARCHIVED ON

TAPE: 2635A-C97006:MT.

SEE SCD: 2635A-C90006.

VCC

C1

C2

C3

C 4

C 7

C8

.1

.1

.1

.1

.1

.1

25V

25V

25V

25V

25V

25V

1TP1

3

 

5

M H 1

8

 

10

M H 2

13

 

15

M H 3

18

 

R 4

R 3

 

 

 

10K

10K

 

 

 

 

VCC

HC4066

 

 

 

U 2

 

 

11

 

10

 

X0

Y0

 

12

 

 

E0

 

 

 

8

 

9

 

X1

Y1

 

6

 

 

E1

 

 

 

4

 

3

 

X2

Y2

 

5

 

 

E2

 

 

 

1

 

2

 

X3

Y3

RESET*

13

 

E3

 

 

 

 

 

 

CRD*

9

OE

CE1*

4 2

CE2

7

CE1

PCMCIA68

U1

U1

U1

U1

U 2

U 3

2635A-1006

s87f.eps

Figure 8-8. A6 Memory Card I/F PCA (2635A) (cont)

8-27

Page 309
Image 309
Fluke 2625A service manual 2635A-1006

2635A, 2625A specifications

The Fluke 2625A is a sophisticated data logger designed for a wide range of industrial and laboratory applications. This versatile instrument excels in capturing and monitoring temperature and voltage measurements with precision and reliability. One of its standout features is its ability to record data from various sensors, making it ideal for environments where comprehensive data acquisition is critical.

Equipped with a large LCD display, the Fluke 2625A provides clear and user-friendly access to real-time measurement data. Its graphical interface allows users to visualize trends and monitor readings easily, which significantly enhances usability. The device supports a variety of input types and can connect to thermocouples, RTDs, and other sensors, offering great flexibility for various measurement tasks.

The Fluke 2625A employs advanced measurement technologies that ensure accuracy in data logging. With a high sampling rate, it captures fast-changing signals while maintaining data integrity. The device features a built-in memory that allows for extensive logging, accommodating long-term monitoring tasks without requiring constant oversight. Users can set it to log data at specified intervals, offering customizable solutions for different monitoring needs.

Another significant characteristic of the Fluke 2625A is its robust communication capabilities. The device supports USB and RS-232 interfaces for easy connectivity with computers and other devices, making data transfer and analysis seamless. This feature is especially beneficial for users who need to compile or analyze large sets of data quickly.

Furthermore, the Fluke 2625A is designed with durability in mind. Its rugged construction makes it suitable for challenging environments, including those with high levels of vibration, dust, or moisture. This reliability ensures that the device can withstand the rigors of fieldwork while still delivering accurate measurements.

In summary, the Fluke 2625A is a powerful data logger that combines versatility, accuracy, and reliability. Its user-friendly interface, advanced measurement technologies, and robust design make it an essential tool for professionals in various industries, from manufacturing and HVAC to research and development. Whether monitoring temperature changes in a laboratory or assessing voltage levels in an industrial setting, the Fluke 2625A stands out as a trusted solution for effective data logging and analysis.