System clock reference selection (" CLK " of the status information area)

You can select the system clock reference.

By selecting " CLK " and pressing the [ENTER/YES] key, you can select the clock reference from among the following (the default is "INT").

To make recording with internal clock reference, select "INT" (default). To make the unit locked to an external digital or word clock, select "Digital" or "Word". In addition, you can select "Video" if the optional TC/SYNC card is installed. You can also select the system clock reference via the "Sync Clock" menu item in the "TC SETUP" menu of the MENU mode (see page 127 for details).

INT

The unit follows the internal clock.

 

 

DIGI

The unit follows a digital input clock.

 

 

WORD

The unit follows an external word clock.

 

 

VIDEO

Available only when the optional TC/SYNC card is installed. The unit follows

an external video clock.

 

 

 

<Note>: When "DIGI" (or "WORD") is selected but the unit does not receive a correct digital (or word) signal or does not lock to the reference signal, "DIGI" (or "WORD" quickly flashes. In such a case, check cable connection, etc.

<Note>: When the system clock is set to "DIGI" or "WORD", the FS of a file to be played back must match the FS setting of the unit. Otherwise, you cannot play back the file.

In such a case, make the FS setting of the unit to match the FS of the file.

Sampling frequency and bit length selection (“ FS/BIT ” of the status information area)

By selecting " FS/BIT " and pressing the [ENTER/YES] key, you can select a sampling fre- quency and bit length combination from among the following (the default is "48/24"). You can also select a sampling frequency and bit length combination via the "Record FS&Bit" menu item in the "SYS SETUP" menu of the MENU mode (see page 117 for details).

Option

FS/BIT

Option

FS/BIT

 

 

 

 

22/16

22.05kHz/16bit

48/24

48kHz/24bit

 

 

 

 

44/16

44.1kHz/16bit

88/24

88.2kHz/24bit

 

 

 

 

48/16

48kHz/16bit

96/24

96kHz/24bit

 

 

 

 

44/24

44.1kHz/24bit

 

 

 

 

 

 

TC generator setting (“ ” of the status information area)

When the optional TC/SYNC card is installed, this item selects the time code recording mode. When the optional TC/SYNC card is not installed, this item selects the recording mode of LTC which is always recorded simultaneously with audio signals.

When the optional TC/SYNC card is not installed, by selecting "" and pressing the [ENTER/YES] key, you can select a desired LTC recording mode between "REC R" and "EXT" (the default is "REC R"). See the table below for details of these modes. You can also select the TC generator setting via the "Gen mode" menu item in the "TC SETUP" menu of the MENU mode (see page 80 and 128 respectively).

 

REC R

The first time you start recording, the generator stamps "01h00m00s00f" as the

 

LTC start time at the beginning of the file, and records LTC jammed to this start

 

(Rec Run)

time code. The next time you start recording, LTC continued from the LTC on the

 

 

previous file is recorded.

 

 

 

 

EXT

Every time you start recording, the generator stamps "01h00m00s00f" as the LTC

 

start time at the beginning of the file, and records LTC jammed to this start time

 

(Ext Run)

 

code. In other words, every file has LTC which starts from "01h00m00s00f".

 

 

 

 

 