5.9 Updating the System

2. In [Model List], select [N1800].

D[Registered System Update] shows the details of the currently available update modules.

3.Press the [Browse] button to specify the update module to be registered.4.Press the [Upload] button to upload the update module.5.Select the [Issue an Update Call] check box to issue an update call.

When the check box is selected, even if a scanner is not started or logged in to, the update module is sent and applied to the scanner according to the Scanner Notification Schedule.

However, if the update is released while the user is logged into a scanner, the update will be applied after the user is logged out. If any other available updates are pending, those are also applied at the same time.

6.In [Scanner Notification Schedule], set the schedule to notify update modules.

When issuing a call, set a time that does not conflict with that set for [Software Update Time-Period Restrictions] on the [Scanner Central Admin Server Settings] window.

7. Press the [Register] button.

DThis registers the uploaded update module.

When a new system update is available, it will be installed in a scanner if the new version is higher than the current version. Targeted scanners are restarted after the new system update has been installed.

Pending updates are performed in the following order:

1.System Updates

2.Add-in Installs

3.Scanner Settings

8.Press the [Back] button.

DThe Central Admin Console main window appears again.

262