Check item

Is the pick roller worn out?

Action

Replace the pick roller.

For more details, refer to "7.5 Replacing Parts" (page 426).

Check item

Is there any foreign matter in the document feed path?

Action

Clean the document feed path.

Scanned Data Is InappropriateScanned data is elongated.

Check item

Are the feed rollers dirty?

Action

Clean the feed rollers.

For more details, refer to "7.3 Cleaning Inside the Scanner" (page 420).

Shadow on the leading edge of the scanned data.

Check item

Are the feed rollers dirty?

Action

Clean the feed rollers.

For more details, refer to "7.3 Cleaning Inside the Scanner" (page 420).

Vertical line on the scanned data.

Check item

Is the glass dirty?

Action

For more details on cleaning the glass, refer to "Chapter 7 Scanner Care" (page 416).

Scanned data appears skewed or distorted.

Check item

Has the document been loaded correctly?

Action

Load the document correctly.

463