zCarbonless paper contains chemical substances that may damage the pad assy or the pick and other rollers when documents are fed. Pay attention to the following: z cleaning

If pick errors occur frequently, clean the pad assy and pick roller.

For details about cleaning the pad assy and pick roller, refer to "Chapter 7 Scanner Care" (page 416).

z Replacing parts

The service life of the pad assy and pick roller may be shortened when compared to scanning only wood containing paper documents.

zWhen wood containing paper manuscripts are scanned, the life of the pad assy and pick roller may be shortened compared with the case where woodfree paper manuscripts are scanned.

zWhen scanning photographs, the face of the photograph may become damaged.

zWhen scanning semi-transparent documents, set the scan [Brightness] to [Light] to avoid image bleed through.

zTo prevent the rollers from becoming dirty, avoid scanning documents containing large areas written or filled in with pencil. If scanning of such documents is unavoidable, clean the rollers frequently.

For details about cleaning the pad assy and pick roller, refer to "Chapter 7 Scanner Care" (page 416).

zTo operate correctly, the leading edges of all document sheets must be evenly aligned. The curling of the leading edge must be within the following tolerances:

More than

 

30 mm

Feed direction

 

Less than 3 mm

Leading edge

Side being

of document

scanned

More than

 

30 mm

Feed direction

Less than 5 mm

 

Leading edge

Side being

of document

scanned