GE Monogram ZIS42N, ZISB42D Design Information, Built-In Refrigerator, True Flush Installation

Models: ZISW42D ZISB42D ZIS42N

1 48
Download 48 pages 63.35 Kb
Page 3
Image 3
Design Information

Flush or Semi-Flush Enclosure Installations

Design Information

42" Built-In Refrigerator

Advance Planning

DESIGN INFORMATION

0"

42" Built-In Refrigerator True Flush Installation

In a flush installation, the refrigerator doors will align evenly with the

front face of adjacent cabinet doors. The refrigerator blends into the surrounding cabinetry.

Monogram built-in refrigerators can be installed flush with typical 24-3/4" deep cabinetry.

When installed semi-flush, the case trim will conceal slight gaps around the enclosure. The refrigerator will project forward approximately 3/4" beyond the front face of surrounding cabinetry.

In any installation situation, a wide range of appear- ance options can be accomplished through the use of one or more trim kits. See trim kit descriptions and appearance options on page 5.

 True Flush Installation 3/4" Side Panel Requirements:

Semi-Flush Installation These refrigerators can also be installed

semi-flush into an enclosure using the minimum cutout width. The case trim creates a frame around the opening.

Side Panel Requirements:

Side panels are not required whenever the refrigerator is installed into an enclosure or between pantry and oven cabinets.

Side panels are required whenever the sides of the refrigerator are exposed.

Side panel sizes vary depending on the type of installation being made.

To accomplish an attractive installation, you must:

1.Determine the need for side panels.

2.Determine side panel thickness.

3.Order matching side panels from the cabinet manufacturer. Be sure to provide the exact dimensions.

Enclosure

Cutout and

Product

Dimensions

• To achieve a flush fit the finished cutout width must

 

 

 

 

 

 

*Finished Width

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

be at least 42" wide.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall View

• A semi-flush installation requires 41-1/2" min. finished

 

 

 

 

 

 

 

7"

 

 

 

 

 

 

 

 

 

 

 

cutout width.

 

 

 

 

 

 

Electrical

 

 

 

 

 

5"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The electrical and water locations must be located as

 

 

 

 

 

Area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shown for either type of installation.

 

 

 

 

 

 

 

 

 

18 3/8"

 

 

 

 

 

 

84 1/2"

max

 

 

24 3/4" Total

 

 

 

 

 

74" From Floor

 

 

 

 

83-1/4" min

 

 

 

 

Depth

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to Bottom

 

 

 

 

Finished

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of Electrical

 

 

 

 

Opening

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

83" Min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

84-1/2" Max

 

 

 

 

5"

 

Water Supply

 

 

5"

 

 

3 1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42"

 

*42" Min. for a flush installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24-3/4"

 

 

 

 

 

 

 

 

 

 

41-1/2" Min. for a semi-flush installation

 

 

 

 

 

 

 

 

Note: Additional cutout width may be required when

 

 

 

 

side panels are used. Add side panel thickness to the

 

 

 

 

finished cutout to calculate rough-in width. See

 

 

 

 

installation examples on the following page.

3

Page 3
Image 3
GE Monogram ZIS42N, ZISB42D Design Information, Built-In Refrigerator, True Flush Installation, Side Panel Requirements